Installation

BEFORE STARTING

o
This product is for indoor use only
o
These instructions generally assume the use of OutBack
products from the front page; instructions may differ if not used
o
If GSLC is not used, make certain all electrical connections
meet local safety standards and codes
Materials In Box
o
o
Inverter
Quick Start Guide
(this document)
o
Mounting Bracket
o
RTS
o
Hardware Kit
(Remote Temperature Sensor)
0.5" (1.3 cm)
0.5" (1.3 cm)
16" (40.6 cm)
(34.8 cm)
ON/OFF
INV
RELAY
+ -
Switch
Remote
Battery
AUX
12V
INV
Temp
AUX
stacking
multiple
inverters:
45.0"
For GSLC door
(114.3
clearance, space
cm)
systems 0.9"
N
L1 L2
N
L1 L2
L1 L2
N
E
E
E
OUT
GEN
GRID
U
U
U
(3.2 cm) apart.
900-0162-01-01 REV A Sheet 1 of 3
©2017 OutBack Power Technologies. All Rights Reserved.

Tools Required

o
Wrench and socket sets; should include

torque and ratchet wrenches

reversible (stubby) wrenches for narrow access

offset box wrench, ½" or 13 mm
o
Wire cutters/strippers
o
Insulated screwdriver set (flat and Phillips);
should include

#2 Phillips screwdriver 15 to 16" long
o
Long-nose pliers
o
High-resolution voltmeter
8.75"
(22 cm)
Wall Stud
Wall Board
Plywood
(Optional)
3
13.7"
Inverter
Bracket
Wall
Bracket
28.0"
29.1"
(71.1 cm)
(74.0 cm)
When
1
Ensure the mounting surface is strong enough to handle 3 times the total
weight of all the components. Add plywood or other reinforcing material as
necessary to strengthen the surface.
2
Attach the wall bracket. Center the mounting holes on the wall studs. Use all
6 mounting screws to secure the bracket.
3
Lift the inverter so that the inverter bracket is above the wall bracket.
4
Lower the inverter so that the inverter bracket slips into the wall bracket.
5
To install the GSLC, unscrew the inverter bottom screws approximately ¼"
(0.6 cm) to 3/16" (0.5 cm).
6
Align the GSLC along the bottom of the inverter. Slide the bottom screws
into the keyhole slots.
7
Mark the spots for the GSLC mounting feet. (If necessary, remove the
GSLC to install wall anchors.) Install screws to secure the feet.
8
Follow the appropriate instructions for installing other components.
Different mounting locations are available.
Wall
16" (40.6 cm)
Stud
1
Plywood (Optional)
4.1"
2
Wall Bracket
(10.4 cm)
4
6.0" (15.2
cm)
14.0"
(35.6 cm)
12.0"
(31.8 cm)
7
Wall
Stud
5.0"
(12.7 cm)
Wall Board
Left Side:
8.0" (20.3
The Radian allows two locations for the
cm)
system display mounting bracket.
8
The Radian has one
mounting location for
the HUB product.
The GSLC also has
one location.
5
Bottom
Screws
Keyhole Slots
6
Right Side:
The FLEXmax charge controller
is mounted with brackets. Two
controllers can be mounted side
by side with larger brackets
(using the forward holes to allow
for conduit).
The Radian has two sets of
bracket positions. The GSLC
has one set.
NOTE: The FLEXmax 100
charge controller attaches
directly to the wall, not the
Radian system.