Toshiba RAV-SM304MUT-E Service Manual page 62

Indoor unit digital inverter: compact 4-way cassette type; concealed duct type; ceiling type
Hide thumbs Also See for RAV-SM304MUT-E:
Table of Contents

Advertisement

TA, TC, TCJ, TE, TS, TO sensor
Representative value
Temperature
(Minimum
(°C)
value)
0
32.33
10
19.63
20
12.23
25
9.75
30
7.764
40
5.013
50
3.312
60
2.236
70
1.540
80
1.082
90
0.7740
100
0.5634
40
30
20
10
0
200
150
100
50
0
AMP Air Conditioning
Temperature – Resistance value characteristic table
Resistance value (kΩ Ω Ω Ω Ω )
(Standard
(Maximum
value)
value)
33.80
35.30
20.35
21.09
12.59
12.95
10.00
10.25
7.990
8.218
5.192
5.375
3.451
3.594
2.343
2.454
1.623
1.709
1.146
1.213
0.8237
0.8761
0.6023
0.6434
TA, TC, TCJ, TE, TS, TO sensor
0
10
20
30
0
10
20
30
Representative value
Temperature
(°C)
0
10
20
25
30
40
50
60
70
80
90
100
40
50
60
70
Temperature (˚C)
TD, TL sensor
40
50
60
70
Temperature (˚C)
– 62 –
www.ampair.co.uk | sales@ampair.co.uk
TD, TL sensor
Resistance value (kΩ Ω Ω Ω Ω )
(Minimum
(Standard
value)
value)
150.5
161.3
92.76
99.05
58.61
62.36
47.01
49.93
37.93
40.22
25.12
26.55
17.00
17.92
11.74
12.34
8.269
8.668
5.925
6.195
4.321
4.507
3.205
3.336
80
90
100
20
15
10
5
0
80
90
100
(Maximum
value)
172.7
105.6
66.26
52.97
42.59
28.03
18.86
12.95
9.074
6.470
4.696
3.468

Hide quick links: