• TEMPERATURE
Press
button.
Each time
this button is pressed, setting temperature rises
1°C.
Each time
this button is pressed, setting temperature lowers
1°C.
NOTE
The setting is impossible for fan operation.
• STOP OPERATION
Press
button.
OPERATION lamp goes off and the air conditioner stops opera-
tion.
Do not turn off the power supply immediately after the
operation is stopped. Make sure to wait for 5 minutes or more
to avoid water leakage and malfunction.
Characteristic of the heating operation
DEFROST OPERATION
Outdoor Temperature and
Heating Capacity
English
CAUTION
• As the frost on the coil of an outdoor unit increases, heating effect decreases and
the system automatically goes into DEFROST OPERATION.
• The hot air stops, and the remote controller display shows "
(DEFROST/HOT START).
• After 6 to 8 minutes (maximum 10 minutes) of DEFROST OPERATION, the system
returns to HEATING OPERATION.
• The heating capacity declines along with the decrease of outdoor temperature. In
that case, please use the air conditioner concurrently with another heater.
• This air conditioner belongs to the hot-air circulating type and therefore it may take
some time for the indoor temperature to go up.
• If the hot air can not reach your feet, please use the circulator (indoor circulating
fan). Please contact the dealer for details.
OPERATION RANGE
If the temperature or the humidity is beyond the following condi-
tions, safety devices may work and the air conditioner may not
operate, or sometimes water may drop from the indoor unit.
• INDOOR UNIT
Indoor
MODE
Temperature
Cooling
21~32°C
Heating
15~27°C
SETTING
Indoor
TEMPERATURE
Humidity
RANGE
80% or below
15~32°C
15~32°C
"
9