INSTALLATION AND OPERATION MANUAL
Split System air conditioners
FDYMP71L7V1
FDYMP100L7V1
FDYMP125L7V1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FDYMP71L7V1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FDYMP71L7V1

  • Page 1 INSTALLATION AND OPERATION MANUAL Split System air conditioners FDYMP71L7V1 FDYMP100L7V1 FDYMP125L7V1...
  • Page 2 ≥300 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 X40A °C DB 18~35 RP71~125 –15~46 °C WB 14~25 °C DB 18~35 ≤80% RYP71~125 –5~46 °C WB 12~25 °C DB...
  • Page 3 ™ËÌ›ˆÛË Nota tal como estabelecido no Ficheiro Técnico de Construção DAIKIN.TCF.016 e com o parecer positivo de KEMA de acordo com o Certificado 81728-KRQ/EMC98-4341 . Bemærk som anført i den Tekniske Konstruktionsfil DAIKIN.TCF.016 og positivt vurderet af KEMA i henhold til Certifikat 81728-KRQ/EMC98-4341 .
  • Page 4: Table Of Contents

    ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY Refrigerant piping work ..............3 TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE Drain piping work ................3 SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A Electric wiring work ................
  • Page 5: Selecting Installation Site

    The refrigerant charge in the system might not be clear. For other installation than standard installation, contact your This to avoid confusion for future maintenance and serving of Daikin dealer for details. the installation. The fan speed for this indoor unit is preset to provide high external static pressure.
  • Page 6: Indoor Unit Installation

    Table 1 NDOOR UNIT INSTALLATION Flare When installing optional accessories read also the installation Pipe dimension A gauge Tightening torque (mm) Flare shape manual of the optional accessories. Depending on the field conditions, it may be easier to install optional accessories before the Ø9.5 32.7~39.9 N•m 12.0~12.4...
  • Page 7: Electric Wiring Work

    Precautions LECTRIC WIRING WORK Observe the notes mentioned below when wiring to the power supply terminal board. General instructions • Do not connect wires of different gauge to the same power supply terminal. (Looseness in the connection may cause All field supplied parts and materials and electric works must overheating.) conform to local codes.
  • Page 8: Field Setting

    Precautions Computerised control (forced off and on/off operation) A single switch can be used to supply power to units on the same Wire specifications and how to perform wiring system. However, branch switches and branch circuit breakers must Connect the input wire (option) to connector X40A on the be selected carefully.
  • Page 9: Operating The Unit

    Use of wire or copper wire may cause the unit to NOTE Contact your Daikin dealer in case of changing the break down or cause a fire. combination or setting of group control and two remote Never insert objects such as sticks into the air inlet or controller control systems.
  • Page 10: Not A Malfunction Of The Air Conditioner

    It is Check if the air filter is clogged. necessary to clean the inside of the indoor unit. Ask your Daikin Ask a qualified service person to clean the air filter. dealer for details on cleaning the unit. This operation requires a The system operates but it does not sufficiently cool or heat.
  • Page 11: Maintenance

    How to clean air outlet AINTENANCE Clean with soft cloth. When it is difficult to remove stains, use water or neutral Only a qualified service person is allowed to perform detergent. maintenance. Before obtaining access to terminal devices, all power NOTE Do not use gasoline, benzene, thinner, polishing supply circuits must be interrupted.