KROHNE BM 70 A Installation And Operating Instructions Manual page 73

Level, non-contact level gauging using electromagnetic waves
Table of Contents

Advertisement

Wave-Stick:
Environment class
Protection category
Shock resistance
Vibration endurance limit
EMC
6.3
Product conditions
Physical properties
Relative permittivity
Limitations
Temperature of product
Operating pressure
Horn antenna/Wave-Guide
Wave-Stick
7
Component parts
Dimensions and weights
Materials
Housing: signal converter
Flange system, antenna, extension
Gaskets
Wave-Stick
Process connection
Horn antenna/Wave-Guide
Wave-Stick
Dairy screw connection
Tri-Clamp connection
Electrical connection
8
User interface
Keypad
Magnetic sensors
Local display
User language
Units of measurement
9
Power supply
24 V DCAC
115/230 V AC
Power consumption
Installation and operating instructions BM 70 A/P
(Tamb ≤ 55°C/131°F):
Horn antenna, Wave-Guide
High-temperature version with:
- FFKM gasket
(Kalrez 4079/Parofluor V8545-75):
- Kalrez 2035 gasket:
- Viton gasket:
- FEP-sheathed gasket:
pressure-dependent up to +150°C/302°F
Locations exposed direct to open-air climate, D1 Severity in conformity with
EN 60654-1
(signal converter) IP 66 / IP 67
Impact test to EN 61010, Sect. 8.2 with 0.5 J energy; drop test to
prEN 50178
IEC 68-2-6 and prEN 50178 (10-57Hz:0.075 mm/57-150 Hz:1 g)
EN 50081-1, EN 50082-2; NAMUR Recommendation
No effect on measurement results; to ensure reliable measurements, the
relative permittivity should have the following minimum values:
ε r > 1.5; ε r < 3: stilling well recommended; Wave-Stick immersed: ε r > 4
Liquid a mmonia (NH 3 ); liquid hydrogen (H 2 ); liquid helium (He)
unrestricted (but be aware of ambient and flange temperatures)
dependent on flange size and pressure rating (see Table)
Standard: max. 64 bar (higher on request)
bar psig
+16
232
(46 - 0.3·T[°C]) bar
(740 - 2.4·T[°F]) psig
Pressure
+1
+15
-1
-15
-20
+100
+150 °C
Temperature T
-4
+212
+302 °F
see Sect. 7.2
Aluminium with electrostatic powder coating; sight window: glass
Stainless steel 1.4571 or 1.4435, Hastelloy C4 or B2, titanium, tantalum;
(other materials on request)
FFKM (Kalrez 4079 or Parofluor V8545-75); Kalrez 2035; Viton (FPM); FEP-
sheathed (basically, all versions include PTFE as the material in contact with
the product)
only PTFE in contact with product; flange made of 1.4571 (316 Ti)
DIN 2501 / DIN 2526, Form C
ANSI B 16.5
DIN 2501 / DIN 2526, Form C
ANSI B 16.5
DIN 11 851
SMS 1145
ISO 2852
Cable entries:
3x M25×1,5
Terminals:
0.5-2.5 mm² (solid conductor: max. 4 mm²)
PE or FE and PA:
U-clamp terminal (max. 4 mm²)
Shielding for RS 485 cable and for current output cable > 100 m
3 keys
operation with magnetic pin without opening the housing
2-line illuminated LCD + 6 status markers
German, English, French, Italian, Spanish, Portuguese, Swedish
Length: m, cm, mm, inch, ft, %
Volume: m³, Liter, US Gal, GB Gal, ft3, bbl, %
Conversion unit: any text
18-31.2 V DC or 18-26.4 V AC (45-66 Hz)
optionally: 100-120 V AC (tolerance: 85-127V),
200-240 V AC (tolerance: 170-254V); 45-66 Hz
Typically 7.5 - 10 W / 12 VA
Page: 73
(
-30...+120°C
-22...+248°F)
(
-30...+250°C
-22...+482°F)
(safety limit 280°C/536°F)
(
-30...+210°C
-22...+410°F)
(
-30...+200°C
-22...+392°F)
(
-30...+200°C
-22...+392°F)
(
-20...+100°C
-4...+212°F)
DN 50 ... DN 200 / PN 6 ... PN 64;
2'' ... 8'', Class 150/300 lb/RF;
DN 50 ... 150;
2'' ... 6'';
DN 50, DN 65, DN 80
51 mm, 63 mm, 76 mm
2'' ... 4''