8.6.10 Display
Language of display texts
A choice of languages for the display texts is offered in
Fct. 3.4.1.
GB/USA English
D
German
F
French
I
Italian
Coding desired for entry into setting level?
Set NO or YES in Fct. 3.4.2 ENTRY.CODE1.
If NO set, simply press key → to get into the setting
level.
If YES set, press key → and then a 9-keystroke combi-
nation to get into the setting level.
Factory-set Entry Code 1:
→ → → ↵ ↵ ↵ ↑ ↑ ↑
To change Entry Code 1
Select Fct. 3.4.2 ENTRY CODE 1: set to YES.
Select Fct. 3.4.3 CODE 1.
Press key → , display shows: CODE 1 _ _ _ _ _ _ _ _
_
Key-in required 9-keystroke combination; each key-
stroke confirmed by "*". Then press the same
keystroke
combination
(= incorrect entry) appears if 1st and 2nd entries are
not equal.
and → and repeat entries.
Press keys
Take good note of the selected entry code!
Measuring-point identification (tag name)
A max. 8-figure tag name can be set under Fct. 3.4.4
LOCATION (e.g. L123 A53)
Characters assignable to each of the 8 places:
alpha characters A-Z / a-z; numbers 0-9;
special signs: + - ; blanks (= underscore character)
Factory setting: BM70A-00 or BM70P-00
8.6.11 Auto tank height
FCT. 3.5.1 AUTO TANKH.
With this function the height of the tank can be determined
by the BM 70 A/P itself, provided the following conditions
are met:
The tank has been completely drained for at least 2
minutes.
The tank bottom has good reflectivity (not suitable for
dished and tapered bottoms without reference plate).
The
functions
Fct.
3.1.3
(extension), Fct. 3.1.5 (distance piece) and Fct. 3.1.6
(stilling well) must previously have been correctly set.
If the tank is taller than 30 m, the approximate tank
height must previously be set manually with Fct. 3.1.1,
as otherwise the measuring range will not suffice to
locate the bottom.
After pressing the → key the display shows the currently
measured value for the tank height. Press key
inquiry "SURE NO" now appears. If you are not sure
whether the measured value coincides with the true tank
height, reject the value by pressing key
If the measured value seems plausible for the tank height
and you wish to store it, change the option to "SURE YES"
by pressing key ↑, and then press key
Installation and operating instructions BM 70 A/P
E
Spanish (Español)
P
Portuguese
S
Swedish
again.
"WRONG
CODE"
(antenna),
Fct.
3.1.4
; the
.
.
If the message: NO MEAS.VAL. appears, this means that
the quality of measurement is not adequate (inadequate
bottom reflection or too many interferences) for automatic
determination of the tank height. Press key
operation. In this case you will need to enter the tank
height manually with Fct. 3.1.1.