KROHNE BM 70 A Installation And Operating Instructions Manual page 41

Level, non-contact level gauging using electromagnetic waves
Table of Contents

Advertisement

Function (Fct.)
Enter range
3.4
USER DATA
3.4.1 LANGUAGE
Options
3.4.2 ENTRY CODE 1
Options
3.4.3 CODE 1
Enter code
3.4.4 LOCATION
Text
3.5
APPLICAT.
3.5.1 AUTO TANKH.
Special function
3.5.2 EMPTY.SPEC.
Options
3.5.3 TIMECONST.
Value
3.5.4 TRACING.VEL.
Value
0.01 ... 10.00 [m/Min] (BM 70 A)
0.01 ... 1.00 [m/Min] (BM 70 P)
3.5.5 MULT.REFL.
Options
3.5.6 BD-DETECT.
Options
3.5.7 FUNCT. FTB
Options
3.5.8 EPSILON R
Enter
3.5.9 TANKTYPE
Options
3.6
SW.OUTP.S.
3.6.1 FUNCTION S
Options
3.6.2 TYPE S
Option
3.6.3 THRESHOLD
Value
3.6.4 HYSTERESIS
Value
*:
Default values following a parameter reset (use of a new EEPROM not yet described).
The factory setting for the parameters marked with * is dependent upon the device version and
customer specifications (if the tank height is known at the time the order is placed).
Installation and operating instructions BM 70 A/P
Default value
GB/USA,
GB/USA *
D, F, I, E, P, S
NO
NO
YES
RRREEEUUU
BM70A-00
BM70P-00
OFF
OFF *
ON
RECORD
1 ... 100 [s] (BM 70 A)
10 s (BM 70 A)
10 ... 100 [s] (BM 70 P)
30 s (BM 70 P)
0.50 m/min
(BM 70 A)
0.10 m/min
(BM 70 P)
NO
NO
YES
NO
YES
YES
OFF
OFF
PARTIAL
FULL
2.0000
1.1000 ... 8.0000
STORAGE TANK
PROC.TANK.
PROC.TANK.
AGITATOR
OFF
ERROR OPEN
LEVEL
DISTANCE
CONVERSION
REFLECTION
ERROR OPEN
ERROR CLOSED
HIGH
HIGH
LOW
-200.00 ... +200.00 [m]
5.00 m
0.00 ... 99999.99 [m 3 ]
5.00 m 3
0 ... 100 [Refl.]
50
0.00 [m] ... Tank height
0.10 m
0.00 ... 99999.99 [m 3 ]
0.10 m 3
0 ... 100 [Refl.]
10
Description
Select language to be used in the display
(English, German, French, Italian, Spanish, Portu-
guese, Swedish)
Switch the access lockout for the configuration menu
on/off.
Input of the Entry Code.
Input of a max. 8-character device identifier.
Automatic determination of the tank height.
Switch the empty-tank spectrum (profile of the empty
tank) on/off, or make new recording.
Input of the time constant for measured-value filtering
(low-pass).
Input of the maximum rate of change in the level that
can occur in operation.
Switch the multi-reflection identifier on/off.
Switch the block distance (overfill) detector on/off.
Select function of the tank bottom tracking system.
(FULL for BM 70 A only)
Input of the relative permittivity of the product for the
tank bottom tracking system.
Select the tank type.
(AGITATOR for BM 70 A only)
Select the function of the switching output.
Select type of limit value for the switching output.
(not applicable to Function OFF, ERROR OPEN or
ERROR CLOSED)
Input of the threshold value for the switching output.
(Input is dependent on the function of the switching
output. The values for level and distance include the
tank bottom and reference offset, resp.)
Input of the hysteresis for the switching output.
(Input is dependent on the function of the switching
output.)
Page: 41
11/00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bm 70 p

Table of Contents