Switching output
characteristics
Sw.output application
Examples
see Sect. 8.5
Error message
Contact opens
when error occurs
Contact closes
when error occurs
Limit value, level
- Contact closes when
upper limit exceeded
- Contact closes when
lower limit exceeded
Limit value, distance
- Contact closes when
upper limit exceeded
- Contact closes when
lower limit exceeded
Limit value, conversion
- Contact closes when
upper limit exceeded
- Contact closes when
lower limit exceeded
Limit value, reflection
- Contact closes when
upper limit exceeded
- Contact closes when
lower limit exceeded
e.g. operation indicator
Contact closed when
supply power applied
and open at power fail
Installation and operating instructions BM 70 A/P
FUNCTION S:
LEVEL
Fct. 3.6.1
DISTANCE
CONVERSION
REFLECTION
THRESHOLD
Fct 3.6.3
TYPE S
Fct. 3.6.2
Switching output
HIGH
open
closed
LOW
closed
open
Switching function
settable by way of ...
Fct. 3.6.1
Fct. 3.6.2
FUNCTION S
TYPE S
ERROR
no *
OPEN
ERROR
no *
CLOSED
LEVEL
HIGH
LEVEL
LOW
DISTANCE
HIGH
DISTANCE
LOW
HIGH
CONVERSION
CONVERSION
LOW
REFLECTION
HIGH
REFLECTION
LOW
OFF
no *
Overflow
= Threshold + Hysteresis / 2
HYSTERESIS
Fct. 3.6.4
Underflow
= Threshold + Hysteresis / 2
open
closed
closed
open
Further parameters
settable via ...
Fct. 3.6.3
Fct. 3.6.4
THRESHOLD
HYSTERESIS
no *
no*
no *
no*
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
no *
no *
Page: 54
* Setting has no effect on the
function of the switching output!
Overflow =
Measured value higher than limit
value
(= threshold plus hysteresis / 2)
Underflow =
Measured value lower than limit
value
(= threshold minus hysteresis / 2)