GE G30 Instruction Manual page 542

Ur series generator protection system
Hide thumbs Also See for G30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 54 of 60)
ADDR
REGISTER NAME
C908
...Repeated for Direct Input 31
C90C
...Repeated for Direct Input 32
Direct Input/Output Alarms (Read/Write Setting)
CAD0
Direct Input/Output Channel 1 CRC Alarm Function
CAD1
Direct Input/Output Channel 1 CRC Alarm Message Count
B
CAD2
Direct Input/Output Channel 1 CRC Alarm Threshold
CAD3
Direct Input/Output Channel 1 CRC Alarm Events
CAD4
Reserved (4 items)
CAD8
Direct Input/Output Channel 2 CRC Alarm Function
CAD9
Direct Input/Output Channel 2 CRC Alarm Message Count
CADA
Direct Input/Output Channel 2 CRC Alarm Threshold
CADB
Direct Input/Output Channel 2 CRC Alarm Events
CADC
Reserved (4 items)
CAE0
Direct Input/Output Ch 1 Unreturned Messages Alarm
Function
CAE1
Direct Input/Output Ch 1 Unreturned Messages Alarm Msg
Count
CAE2
Direct Input/Output Ch 1 Unreturned Messages Alarm
Threshold
CAE3
Direct Input/Output Ch 1 Unreturned Messages Alarm
Events
CAE4
Reserved (4 items)
CAE8
Direct Input/Output Ch 2 Unreturned Messages Alarm
Function
CAE9
Direct Input/Output Ch 2 Unreturned Messages Alarm Msg
Count
CAEA
Direct Input/Output Ch 2 Unreturned Messages Alarm
Threshold
CAEB
Direct Input/Output Channel 2 Unreturned Messages Alarm
Events
CAEC
Reserved (4 items)
Remote Devices (Read/Write Setting) (16 modules)
CB00
Remote Device 1 GSSE/GOOSE Application ID (GOID)
CB21
Remote Device 1 GOOSE Ethernet APPID
CB22
Remote Device 1 GOOSE Dataset
CB23
Remote Device 1 in PMU Scheme
CB24
Reserved
CB25
...Repeated for Device 2
CB4A
...Repeated for Device 3
CB6F
...Repeated for Device 4
CB94
...Repeated for Device 5
CBB9
...Repeated for Device 6
CBDE
...Repeated for Device 7
CC03
...Repeated for Device 8
CC28
...Repeated for Device 9
CC4D
...Repeated for Device 10
CC72
...Repeated for Device 11
CC97
...Repeated for Device 12
CCBC
...Repeated for Device 13
CCE1
...Repeated for Device 14
CD06
...Repeated for Device 15
CD2B
...Repeated for Device 16
Remote Inputs (Read/Write Setting) (32 modules)
CFA0
Remote Input 1 Device
CFA1
Remote Input 1 Bit Pair
CFA2
Remote Input 1 Default State
B-62
RANGE
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
---
0 to 16383
0 to 16
0 to 1
0 to 3
1 to 32
0 to 96
0 to 3
G30 Generator Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
---
F209
"Remote Device
---
1
F001
---
1
F184
---
1
F126
---
1
F626
---
1
F001
---
1
F156
---
1
F086
DEFAULT
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
1"
0
0 (Fixed)
0 (No)
0 (None)
1
0 (None)
0 (Off)
GE Multilin