Teleprotection Channel Tests; Remaining Connection Status - GE G30 Instruction Manual

Ur series generator protection system
Hide thumbs Also See for G30:
Table of Contents

Advertisement

6 ACTUAL VALUES
PATH: ACTUAL VALUES
STATUS
 TELEPROT CH TESTS
MESSAGE
MESSAGE
MESSAGE
MESSAGE
The status information for two channels is shown here.
CHANNEL 1 STATUS: This represents the receiver status of each channel. If the value is "OK", teleprotection is
enabled and data is being received from the remote terminal; If the value is "FAIL", teleprotection enabled and data is
not being received from the remote terminal. If "n/a", teleprotection is disabled.
CHANNEL 1 LOST PACKETS: Data is transmitted to the remote terminals in data packets at a rate of two packets per
cycle. The number of lost packets represents data packets lost in transmission; this count can be reset to 0 through the

COMMANDS
CLEAR RECORDS
VALIDITY OF CHANNEL CONFIGURATION: This value displays the current state of the communications channel
identification check, and hence validity. If a remote relay ID does not match the programmed ID at the local relay, the
"FAIL" message will be displayed. The "N/A" value appears if the local relay ID is set to a default value of "0", the chan-
nel is failed, or if the teleprotection inputs/outputs are not enabled.
PATH: ACTUAL VALUES
STATUS
 COMM STATUS
 REMAINING CONNECT
MESSAGE
MESSAGE
MESSAGE
MESSAGE
These values specify the remaining number of TCP connections still available for each protocol. Every time a connection is
used, the remaining number of connections decrements. When released, the remaining number of connections increments.
If no connection is made over the specific protocol, the number equals the maximum number available for the specific pro-
tocol.
For example, the maximum number of Modbus TCP connections is 4. Once an EnerVista session is opened on a computer
connected to the UR over Ethernet, the Modbus TCP status shows 3. If the EnerVista application is closed, the Modbus
TCP status shows 4.
Note that the maximum number of PMU TCP connections matches the number of aggregators.
GE Multilin

TELEPROT CH TESTS
CHANNEL 1
STATUS: n/a
CHANNEL 1 LOST
PACKETS:
1
CHANNEL 2
STATUS: n/a
CHANNEL 2 LOST
PACKETS:
1
VALIDITY OF CHANNEL
CONFIGURATION: FAIL
menu.

COMM STATUS REMAINING CONNECT
MMS (max 5)
5
MODBUS TCP (max 4)
4
DNP (max 2)
2
IEC-104 (max 2)
2
PMU TCP (max 4)
4
G30 Generator Protection System

6.2.18 TELEPROTECTION CHANNEL TESTS

Range: n/a, FAIL, OK
Range: 1 to 65535 in steps of 1
Range: n/a, FAIL, OK
Range: 1 to 65535 in steps of 1
Range: n/a, FAIL, OK

6.2.19 REMAINING CONNECTION STATUS

Range: 0 to 5
Range: 0 to 4
Range: 0 to 2
Range: 0 to 2
Range: 0 to 4
6.2 STATUS
6
6-11