GE G30 Instruction Manual page 492

Ur series generator protection system
Hide thumbs Also See for G30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 4 of 60)
ADDR
REGISTER NAME
15FB
Field Contact Output Physical States (8 items)
1603
Field Shared Input States
1604
Field Shared Input Channel States
1605
Field Shared Input Test States
1606
Field Shared Output Operand States
B
1607
Field Latching Output Open Operand States
1608
Field Latching Output Close Operand States
1609
Field Latching Output Open Driver States
160A
Field Latching Output Close Driver States
160B
Field Latching Output Physical States
160C
Field Unit Online/Offline States
160D
Field RTD Input Trouble States
160E
Field Transducer Input Trouble States
Ethernet Fibre Channel Status (Read Only)
1610
Ethernet Primary Fibre Channel Status
1611
Ethernet Secondary Fibre Channel Status
1612
Ethernet Tertiary Fibre Channel Status
Data Logger Actuals (Read Only)
1618
Data Logger Channel Count
1619
Time of Oldest Available Samples
161B
Time of Newest Available Samples
161D
Data Logger Duration
Stator Ground Actual Values (Read Only)
1670
Stator Ground Vn 3rd
1672
Stator Ground Vn V0 3rd
1674
Stator Ground V0 3rd
Sensitive Directional Power Actual Values (Read Only) (2 modules)
1680
Sensitive Directional Power 1 Power
1682
Sensitive Directional Power 2 Power
Restricted Ground Fault Currents (Read Only) (4 modules)
16A0
Differential Ground Current Magnitude
16A2
Restricted Ground Current Magnitude
16A4
...Repeated for Restricted Ground Fault 2
16A8
...Repeated for Restricted Ground Fault 3
16AC
...Repeated for Restricted Ground Fault 4
Field Unit RTD Actuals (Read Only) (8 modules)
16C0
Field RTD x Value
16C1
...Repeated for module number 2
16C2
...Repeated for module number 3
16C3
...Repeated for module number 4
16C4
...Repeated for module number 5
16C5
...Repeated for module number 6
16C6
...Repeated for module number 7
16C7
...Repeated for module number 8
Field Unit Transducer Actuals (Read Only) (8 modules)
16C8
Field Transducer 1 Value
16CA
...Repeated for Field Transducer 2
16CC
...Repeated for Field Transducer 3
16CE
...Repeated for Field Transducer 4
16D0
...Repeated for Field Transducer 5
16D2
...Repeated for Field Transducer 6
16D4
...Repeated for Field Transducer 7
16D6
...Repeated for Field Transducer 8
B-12
RANGE
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 2
0 to 2
0 to 16
0 to 4294967295
0 to 4294967295
0 to 999.9
0 to 999999.999
0 to 999999.999
0 to 999999.999
-2147483647 to 2147483647
-2147483647 to 2147483647
0 to 999999.999
0 to 999999.999
-32768 to 32767
-32.768 to 32.767
G30 Generator Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F134
---
1
F134
---
1
F134
channel
1
F001
seconds
1
F050
seconds
1
F050
days
0.1
F001
V
0.001
F060
V
0.001
F060
V
0.001
F060
W
1
F060
W
1
F060
A
0.001
F060
A
0.001
F060
°C
1
F002
---
0.001
F004
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Fail)
0 (Fail)
0 (Fail)
0
0
0
0
0
0
0
0
0
0
0
0
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents