GE G30 Instruction Manual page 517

Ur series generator protection system
Hide thumbs Also See for G30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 29 of 60)
ADDR
REGISTER NAME
6497
...Repeated for Overfrequency 4
Accidental Energization (Read/Write Grouped Setting)
6650
Accidental Energization Function
6651
Accidental Energization Source
6652
Accidental Energization Arming Mode
6653
Accidental Energization OC Pickup
6655
Accidental Energization UV Pickup
6657
Accidental Energization Offline
6659
Accidental Energization Block
665B
Accidental Energization Target
665C
Accidental Energization Events
665D
Reserved (5 items)
Loss of Excitation (Read/Write Grouped Setting)
666A
Loss Of Excitation Function
666B
Loss Of Excitation Signal Source
666C
Loss Of Excitation Center 1
666D
Loss Of Excitation Radius 1
666E
Loss Of Excitation UV Supervision Enable 1
666F
Loss Of Excitation Pickup Delay 1
6670
Loss Of Excitation Center 2
6671
Loss Of Excitation Radius 2
6672
Loss Of Excitation UV Supervision Enable 2
6673
Loss Of Excitation Pickup Delay 2
6674
Loss Of Excitation UV Supervision
6675
Loss Of Excitation Block
6677
Loss Of Excitation Target
6678
Loss Of Excitation Events
6679
Reserved (5 items)
Sensitive Directional Power (Read/Write Grouped Setting) (2 modules)
6680
Sensitive Directional Power 1 Function
6681
Sensitive Directional Power 1 Signal Source
6682
Sensitive Directional Power 1 RCA
6683
Sensitive Directional Power 1 Calibration
6684
Sensitive Directional Power 1 STG1 SMIN
6685
Sensitive Directional Power 1 STG1 Delay
6686
Sensitive Directional Power 1 STG2 SMIN
6687
Sensitive Directional Power 1 STG2 Delay
6688
Sensitive Directional Power 1 Block
668A
Sensitive Directional Power 1 Target
668B
Sensitive Directional Power 1 Events
668C
Reserved (5 items)
6691
...Repeated for Sensitive Directional Power 2
Third Harmonic Neutral Undervoltage (Read/Write Grouped Setting)
66DA
Third Harmonic Neutral Undervoltage Function
66DB
Third Harmonic Neutral Undervoltage Pickup
66DD
Third Harmonic Neutral Undervoltage Delay
66DE
Third Harmonic Neutral Undervoltage Max Power
66E0
Third Harmonic Neutral Undervoltage Min Power
66E2
Third Harmonic Neutral Undervoltage Volt Supervision
66E3
Third Harmonic Neutral Undervoltage Block
66E5
Third Harmonic Neutral Undervoltage Target
66E6
Third Harmonic Neutral Undervoltage Events
66E7
Reserved (4 items)
GE Multilin
RANGE
0 to 1
0 to 5
0 to 1
0 to 3
0 to 3
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0.1 to 300
0.1 to 300
0 to 1
0 to 65.535
0.1 to 300
0.1 to 300
0 to 1
0 to 65.535
0 to 1.25
0 to 4294967295
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 359
0 to 0.95
-1.2 to 1.2
0 to 600
-1.2 to 1.2
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 30
0 to 600
0 to 30
0 to 30
0 to 1.25
0 to 4294967295
0 to 2
0 to 1
0 to 65535
G30 Generator Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
1
F167
---
1
F193
---
0.001
F003
---
0.001
F003
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
ohm
0.01
F001
ohm
0.01
F001
---
1
F102
s
0.001
F001
ohm
0.01
F001
ohm
0.01
F001
---
1
F102
s
0.001
F001
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
degrees
1
F001
degrees
0.05
F001
pu
0.001
F002
s
0.01
F001
pu
0.001
F002
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
pu
0.0001
F003
s
0.01
F001
pu
0.001
F003
pu
0.001
F003
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
DEFAULT
0 (Disabled)
0 (SRC 1)
0 (UV AND
B
OFFLINE)
300
500
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
800
1 (Enabled)
50
1200
1000
1 (Enabled)
500
700
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0
0
100
50
100
2000
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
3000
0
200
200
500
0
0 (Self-reset)
0 (Disabled)
0
B-37