4.
Setting of the needle bar and of the hook
4.1
Hook height
Rule:
The distance A should be 1.0 up to 1.1 mm.
–
Loosen screws (1) and set the height (A) according to the rule.
–
Tighten the screws (1).
Caution: Danger of injury !
Turn the main switch off.
Proceed with the hook setting only with the sewing machine
switched off.
1
EN
23