4.
Setting of the needle bar and of the hook
4.1

Hook height

Rule:
The distance A should be 1.0 up to 1.1 mm.
Loosen screws (1) and set the height (A) according to the rule.
Tighten the screws (1).
Caution: Danger of injury !
Turn the main switch off.
Proceed with the hook setting only with the sewing machine
switched off.