Loosen two screws (3) and the two screws (4). Displace the post
bed feed (5) so that rule 2 is accomplished.
Set the maximum stitch length as described in chapter 2.
Set the needle to the position in which it leaves the throat plate
insert. Dismantle the rear cover and loosen screw (6). Set the
needle manually to the position shown in fig. 1 and tighten
screw (6).
Fig. 1