Chapter 4
Configuring the I/O
44
www.aotewell.com
If a Scanner Configuration dialog box appears, click Yes to continue. The
Edit I/O Parameters dialog box closes and then the 1769-SDN Scanlist
tab dialog box reappears.
20. Click the Input tab to display the input registers for the 1769-SDN
scanner.
21. Click AutoMap to map the drive input image to the 1769-SDN scanner as
shown in the example dialog box below.
TIP
22. Click the Output tab to display the output registers for the 1769-SDN
scanner.
23. Click AutoMap to map the drive output image to the 1769-SDN scanner
as shown in the example dialog box below.
TIP
24. Click OK.
Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013
sales@aotewell.com
If your RSLogix 5000/Logix Designer project requires a different staring
DWord (double word, 32-bit) than the default value of '0' for the drive
input image, set the Start DWord field to the appropriate value.
If your RSLogix 5000/Logix Designer project requires a different staring
DWord (double word, 32-bit) than the default value of '0' for the drive
output image, set the Start DWord field to the appropriate value.