The Monitor Program; Accessing The Monitor Program - Telrad BreezeCOMPACT System Manual

Table of Contents

Advertisement

Chapter 3 - Operation and AdministrationThe Monitor Program
Chapter 3 - Operation and Administration
3.2

The Monitor Program

3.2.1

Accessing the Monitor Program

To access the Monitor program using Telnet:
1
Via the Local Management interface
a
Direct local management using the Monitor program can be performed via the Local
Management interface. The default local management IP Address is 172.31.0.1, and the default
Subnet Mask for this address is 255.255.255.0.
b
The PC used for accessing the Monitor program should be set to IP address 172.31.0.2 or any
other address in the range 172.31.0.2 - 172.31.0.254.
c
Connect the PC to the Ethernet port used for Local Management. In the current release Local
Management interface is always on DAT3 port.
d
Run the Telnet program connecting to IP address 172.31.0.1.
e
The Enter the password message is displayed. Enter the password and press the Enter key to get
to the Main menu. The default password is "installer".
2
Via the External Management interface
a
Management using either SNMP or the Monitor program can also be performed via the External
Management interface. For details on the connectivity parameters of this interface refer to
Interfaces" on page
b
See
interface.
c
Connection of the applicable Ethernet port to the remote management device should typically be
performed via a network device configured to support the External Management Interface VLAN
ID (the default is 12).
d
If the PC is connected to the Ethernet port of the unit via a switching device, the IP address of the
PC should be set to an address in the subnet of the External Management Interface (the default is
IP Address 192.168.1.1 and Subnet Mask 255.255.255.0).
e
If access is via a routing device, configure the Next Hop Gateway parameter of the External
Management Interface (the default is 0.0.0.0 meaning none) to a valid value (in the subnet of the
External Management Interface). Set the IP address of the routing device's port connected to the
unit to the address of the Next Hop Gateway. Set the IP address of the PC according to the IP
configuration of the relevant routing device's port.
BreezeCOMPACT System Manual
45.
"L1 & L2" on page 47
for details on the Ethernet port used for External Management
The Monitor Program
"IP
38