Chapter 2 - CommissioningConfiguring Parameters Required for Management Connectivity
Chapter 2 - Commissioning
External Management IP Address. Must be unique in the managed network. The default is
192.168.1.1. Note that in Unified Connectivity Mode the External Management IP Address should be
within the addresses range defined by BS Bearer IP Address and Bearer Subnet Mask.
External Management Subnet Mask. The default is 255.255.255.0. In Unified Connectivity Mode
should be configured to the value of the Bearer Subnet Mask.
External Management Next Hop Gateway. Must be within the range defined by External
Management IP Address and External Management Subnet Mask. The default is 0.0.0.0 (must be
changed to a valid value if IP address of external management equipment is not within the range
defined by External Management IP Address and External Management Subnet Mask). In Unified
Connectivity Mode should be configured to the value of the Bearer Next Hop Gateway.
External Management VLAN ID. The default is 12. In Unified Connectivity Mode should be configured
to the value of the Bearer VLAN ID. Otherwise it must differ from the Bearer VLAN ID.
Local Management IP Address and Local Management Subnet Mask. You may change the Local
Management IP Address (the default is 172.31.0.1) and Local Management Subnet Mask (the default
is 255.255.255.0). However, it is recommended to always maintain the default value to ensure
availability of known IP parameters for local connectivity.
2.4.4

Configuring the L1 and L2 Parameters (if necessary)

The default Port Negotiation Mode of all ports is auto. Typically auto negotiation mode should be used.
However, if manual setting of physical interface parameters is required for Data Port 2 or Data Port 3 (If
Data Port 1is Up its Port Negotiation Mode is forced to Full Duplex) :
Select the applicable port (BTS>Connectivity>L1 & L2>Select>Port Number>2/3). Select the Update
option.
Configure the Port Negotiation Mode parameter to manual.
Configure the required Port Speed (10/100/100 for Port Number 2, 10/100 for Port Number 3).
Configure the required Duplex Mode.
2.4.5
Configuring the SNMP Authorized Manager and Traps
Manager
2.4.5.1
Configuring the Authorized Manager
By default the unit is supplied with one SNMP Traps Manager with the following parameters:
Manager Number: 1
Community Read Only: public
Community Read and Write: private
If different communities are used by the management system, you should add an SNMP Authorized
Manager with the correct communities or update the existing one.
BreezeCOMPACT System Manual
Configuring Parameters Required for Management Connectivity
30