Step 2 - Co Line Connections - Xblue Networks x16 Installation Manual

Hide thumbs Also See for x16:
Table of Contents

Advertisement

X16 Installation Guide
Step 2 – CO Line Connections
The X16 system supports a single CO Line per port, or two CO lines in
ports labeled
.
1/2 and 3/4
Note:
The port labeled "Line 1" is a direct access auxiliary port for line 1 allowing an
analog device direct access.
Telephone lines are usually found on the center pair (White/Blue) of the
telephone jack (RJ11). Sometimes a second line will be connected to the
outer pair (White/Orange). The system is design to accommodate both types
of installations. When using only the center pair, connect 1 telephone line to
each of the 4 ports in the system. When using both the center and outer
pairs, use only ports labeled 1/2 and 3/4 to connect all 4 lines. The existing
cabling will determine how the telephone lines will be connected to the
system.
Note:
The port labeled "Line 1" gives you access to the telephone company line
(white/blue) plugged into the Central Office Port labeled 1/2. This is useful during a Power
Failure or anytime you want to access to line 1 from an Analog telephone.
Line
AUX CO
CO Line 1
CO Line 2
CO Line 3
CO Line 4
CO Line 5
CO Line 6
- 14 -
6 5
4 3/4 2 1/2 AUX
CO Lines
Port Number
Line1
1 / 2
2
3 / 4
4
5
6
Issue 2
Troubleshooting
Trouble
Possible Causes
The Blue LED "Heartbeat"
AC Cord or Power adaptor
is not functioning.
is not working correctly or
not plugged in correctly.
Sluggish Performance at
Cable Pairs connect to one
Key Telephone –
or more KSU digital ports
• Press Speakerphone
without a telephone
several time with no
connected
reaction
• Lift/Replace Handset
with no reaction
Telephone LCD Shows:
Cable Pairs Connected to
"No Link to KSU"
one or more KSU digital
ports without telephone
installed
Telephone reports:
Cable pairs connected to
"Register Fail" or cycles
one or more KSU digital
between "Register Fail"
ports without a telephone
and "Initializing, Please
connected.
Wait!"
One or more extensions
Not all extensions are
are experiencing static or
punched down.
distortion.
Issue 2
Action
Remove all of the plugs and
re-plug them back in.
• Remote Connection of
un-terminated cable pair
at KSU port
• Install telephones at all
locations wired
• Remove connection of
un-terminated cable
pairs at the KSU.
• Install telephone at all
locations which are
wired.
• Remove connection of
un-terminated cable
pairs at the KSU.
• Install telephone at all
locations which are
wired.
• Remove connection of
un-terminated cable
pairs at the KSU.
• Install telephone at all
locations which are
wired.
- 59 -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents