Function

7.3 Items which can be monitored

Operation mode: Monitor mode
Item
Display
0
Rotation speed
opE0
Operation data No.
AL00
Alarm
_ w n00
Warning
i o
I/O monitor

7.4 Setting the operation data

Up to 4 operation data can be set using the operation panel, and the motor can be
operated by selecting the data based on a combination of ON/OFF status of the M0
and M1 inputs.
Refer to p.23 for the setting procedure and operating method.
Operation mode: Data mode
Item
Display*2
rEu
Rotation speed*1
tA
Acceleration time
td
Deceleration time
i n i
Initialization
*1 If the product is operated at 50 Hz when the rotation speed exceeding 1400 r/min has been set, the motor will rotate around 1420 r/min
although it is out of the setting range.
*2 The digit (0 to 3), which represents the operation data number, will be displayed at the end of the string.
rEu0
Operation data No.0:
Note
Do not turn the control DC power supply while the display is blinking after executing the data setting or
initialization. Doing so may damage the data.
−28−
• The motor shaft rotation speed is displayed.
• When the "speed reduction ratio" parameter is set, the rotation speed of the gear
output shaft or the conveyor transfer speed is displayed.
• When the "speed increasing ratio" parameter is set, the rotation speed being
increased by the external mechanism is displayed.
The operation data number presently selected is displayed.
When an alarm generates, the corresponding alarm code is displayed. You can also
check and clear alarm records in addition to resetting alarms.
Refer to p.32 for alarm types, alarm codes and alarm reset.
• Alarm record
Alarm code
1 to 9: Up to the nine most
recent alarm records
When a warning generates, the corresponding warning code is displayed. You can
also check and clear warning records.
Refer to p.34 for warning types and warning codes.
• Warning record
Warning code
1 to 9: Up to the nine most recent alarm records
The ON/OFF status of each I/O signal for the speed controller can be checked. If the
signal is ON, the corresponding digit is lit. If the signal is OFF, the digit is unlit.
Also, the setting voltage of the external speed setter can be checked.
• Input signal
IN5
IN0
IN4
IN1
IN3
IN2
Description
Sets the rotation speed.
Set as the rotation speed of the motor output shaft.
Sets the acceleration time and deceleration time.
Refer to p.21 for details.
Restores the operation data to the initial value.
Description
• Alarm reset∗
∗ Only available when an
alarm generates.
• Output signal∗
OUT0
OUT1
∗ The alarm output is being ON while the
product operates normally.
[r/min]
Rotation
speed
50 Hz: 0, 90 to 1400 r/min
60 Hz: 0, 90 to 1600 r/min
0.0 to 15.0 s
Acceleration time Deceleration time
Setting range
Initial value
[s]
0
0.0