Option Description
OP29
Standard acceleration and deceleration level for
RS 232 interface
OP40
Locking and unlocking of the treadmill
OP41
Locking and unlocking the manual mode
OP42
Locking and unlocking the profile mode
OP43
Locking and unlocking the cardio mode
OP44
Locking and unlocking the test mode
OP45
Report mode display "Index"
OP46
Report mode display "Elevation"
mode and test mode
OP47
Sustain values in display resp. automatic "Reset" OFF = Display values are deleted after pressing START again or
Comment / Display
The selected acceleration and deceleration level is valid for control
and operation via RS232 interface. This option is very helpful if the
peripheral equipment (e.g. ECG, ergospirometry, PC) does not offer a
menu for acceleration and deceleration levels.
flashing, reports: 1 ... 5, (standard: 1) for the acceleration and
deceleration level for all speed commands via RS 232. The maximum
adjustable value depends on the setting of option 28.
Note: If the peripheral equipment sends an acceleration and
deceleration command via the h/p/cosmos coscom protocol, the
selected level in option 29 or in the corresponding command of the
h/p/cosmos coscom protocol.
OFF = After switching on, the treadmill is completely locked / not
accessible. To unlock the treadmill, press the buttons +, - and START
simultaneously.
While locked the display shows "no ACCESS"
ON = treadmill is unlocked / accessible (standard)
OFF = manual mode is locked / not accessible
ON = manual mode is unlocked / accessible (standard)
OFF = profile mode is locked / not accessible
1 ... 6 = profile mode is unlocked / accessible up to the selected profile
number standard: 6
Example: Selected profile number = 3: The profiles 1-3 can be
selected, the profiles 4 – 6 cannot be selected
OFF = cardio mode is locked / not accessible
ON = cardio mode is unlocked (standard)
OFF = test mode is locked / not accessible
1 ... 94 = test mode is unlocked / accessible up to the selected test
profile number standard: 24
selected test number = 5: The test profiles 1-5 can be selected, the
test profiles 6 – 94 cannot be selected
0 = Display alternates (default)
1 = Display permanently in MET
2 = Display permanently in kJ
3 = Display permanently in Watt
After total switch off the default value 0 will be valid again.
0 = Display alternates (default)
in profile
1 = Display permanently in % or degree (°), depending on OP14
2 = Display permanently in "Step"
After total switch off the default value 0 will be valid again.
automatically 2 minutes after having pressed STOP (default)
ON = Display values will be continued (added) after pressing START
again and will not be automatically deleted by pressing STOP.
Display values can only be deleted by pressing the STOP key twice
(time, distance, energy).