NETGEAR GC110 User Manual page 313

Insight managed 8-port gigabit ethernet smart cloud switch with 2 sfp fiber ports
Hide thumbs Also See for GC110:
Table of Contents

Advertisement

Insight Managed 8-Port Gigabit Ethernet Smart Cloud Switch with 2 SFP Fiber Ports
Menu Item
Detection Type
Timer Schedule
8.
Click the Apply button.
Your settings are saved.
The following table describes the nonconfigurable fields on the PoE Port Configuration
page.
Field
High Power
Max Power (mW)
Class
Output Voltage (Volts)
Output Current (mA)
Output Power (W)
Status
Description
The detection type specifies how the port detects the attached PD. Select one of
the following types:
IEEE 802. The port performs a 4-point resistive detection. This is the default
setting.
4pt 802.3af + Legacy. The port performs a 4-point resistive detection, and if
required, continues with legacy detection.
Legacy. The port performs legacy detection.
If you set up a PoE timer schedule, you can assign it to the port by selecting the
schedule from the Timer Schedule menu.
For information about PoE timer schedules, see
page 315. By default, the selection from the menu is None.
If you want to remove a previously assigned timer schedule, select None from the
Timer Schedule menu.
Description
If a port supports High Power mode, the field displays Yes.
The maximum power in milliwatts that the port can provide.
The class defines the range of power a powered device (PD) is drawing from the
switch. The class definitions are as follows:
0: 0.44–16.2W
1: 0.44–4.2W
2: 0.44–7.4W
3: 0.44–16.2W
4: 0.44–31.6W
Unknown. The class cannot be detected, or no PD is attached to the port.
The voltage that is delivered to the PD in volts.
The current that is delivered to the PD in mA.
The power that is delivered to the PD in watts.
The operational status of the port. The possible values are as follows:
Disabled. No power is delivered.
Delivering Power. Power is being drawn by the PD.
Requesting Power. The port is requesting power.
Fault. A problem occurred with the power.
Test. The port is in test mode.
Other Fault. The port is idle because of an error condition.
Searching. The port is not in one of the other states in this list.
Manage Power over Ethernet
313
Set Up PoE Timer Schedules
on

Hide quick links: