Green LED
Light: indicates that
GSM module is powered.
Red
LED: indicates GSM network operation
- Flashing by 2s period = stand by status
- Fast flashing = active connection
SIM cards Status
Green LED
flashing = module registered to
GSM network
Green LED
fix light = Call in progress
4. Network configuration
4.1 - choosing a configuration mode and login
By default, the Link Gate SIP is configured as following:
IP address 1 (IP proxy SIP module GSM 1) = 192.168.1.250 / 255.255.0.0
IP address 2 (IP proxy SIP module GSM 2) = 192.168.1.251 / 255.255.0.0
IP SIP Server (SIP Server internal)
In your web browser enter IP address of Link gate SIP, defaults setting are 192.168.1.250, user is admin, and
password is 1234.
Linkcom France
11 rue du Soleil Levant 92140 CLAMART
Green LED
status of Incoming( ) and
outgoing ( ) call via
individual IP channels
Red LED
indicating channels Error status:
LED is off – stand by mode
LED blink – failure
= 192.168.1.250 / 255.255.0.0
: Indicates the