BASIC OPERATION
Parameter Name
Second pre-charge
768
upper detection level
Second pre-charge
769
time limit
Operation panel
774
monitor selection 1
Operation panel
775
monitor selection 2
Operation panel
776
monitor selection 3
4mA input check
777
operation frequency
4mA input check
778
filter
Operation frequency
779
during
communication error
Acceleration time in
791
low-speed range
Deceleration time in
792
low-speed range
Pulse increment
799
setting for output
power
Control method
800
selection
820
Speed control P gain 1
Speed control
821
integral time 1
822
Speed setting filter 1
Torque control P
824
gain 1 (current loop
proportional gain)
Torque control
integral time 1
825
(current loop integral
time)
Torque detection
827
filter 1
828
Parameter for manufacturer setting. Do not set.
830
Speed control P gain 2
Speed control
831
integral time 2
832
Speed setting filter 2
Torque control P
834
gain 2
Torque control
835
integral time 2
Torque detection
837
filter 2
Analog input offset
849
adjustment
Terminal 4 function
858
assignment
*2
For FR-F820-02330(55K) or lower and FR-F840-01160(55K) or lower
*3
For FR-F820-03160(75K) or higher and FR-F840-01800(75K) or higher
*7
Differs according to the voltage class. (200V class/400V class)
*9
Differs according to types. (FM type/CA type)
*10
The setting is available only with the CA type.
*13
Setting available for standard models only.
38
Initial
Setting Range
Value
0 to 100%,
9999
9999
0 to 3600s,
9999
9999
1 to 3, 5 to 14,
9999
17, 18, 20, 23 to
25, 34, 38, 40 to
45, 50 to 57, 61,
9999
62, 64, 67,
*13
68
, 69, 81 to
96, 98,100,
9999
9999
0 to 590Hz,
9999
9999
0
0 to 10s
0 to 590Hz,
9999
9999
0 to 3600s,
9999
9999
0 to 3600s,
9999
9999
0.1, 1, 10, 100,
1kWh
1000kWh
20
9, 20
25%
0 to 1000%
0 to 20s
0.333s
9999
0 to 5s, 9999
50%
0 to 500%
40ms
0 to 500ms
0 to 0.1s
0s
0 to 1000%,
9999
9999
0 to 20s, 9999
9999
9999
0 to 5s, 9999
9999
0 to 500%, 9999
0 to 500ms,
9999
9999
9999
0 to 0.1s, 9999
0 to 200%
100%
0
0, 4, 9999
Parameter Name
Torque current/Rated
859
PM motor current
Second motor torque
860
current/Rated PM
motor current
864
Torque detection
Torque monitoring
866
reference
867
AM output filter
Terminal 1 function
868
assignment
*10
869
Current output filter
Speed detection
870
hysteresis
Input phase loss
*13
872
protection selection
874
OLT level setting
Regeneration
882
avoidance operation
selection
Regeneration
883
avoidance operation
level
Regeneration
avoidance at
884
deceleration
detection sensitivity
Regeneration
avoidance
885
compensation
frequency limit value
Regeneration
886
avoidance voltage
gain
888
Free parameter 1
889
Free parameter 2
Cumulative power
891
monitor digit shifted
times
892
Load factor
Energy saving
893
monitor reference
(motor capacity)
Control selection
during commercial
894
power-supply
operation
Power saving rate
895
reference value
896
Power unit cost
Initial
Setting Range
Value
0 to 500A,
*2
9999
9999
0 to 3600A,
*3
9999
0 to 500A,
*2
9999
9999
0 to 3600A,
*3
9999
150%
0 to 400%
150%
0 to 400%
0.01s
0 to 5s
0, 4, 9999
0
0.02s
0 to 5s
0Hz
0 to 5Hz
0
0, 1
120/
0 to 400%
*9
110%
0
0 to 2
380V DC/
300 to 800V
*7
760V DC
0 to 5
0
0 to 590Hz,
6Hz
9999
100%
0 to 200%
9999
0 to 9999
9999
0 to 9999
9999
0 to 4, 9999
100%
30 to 150%
Inverter
*2
0.1 to 55kW
LD/SLD
rated
*3
0 to 3600kW
*9
capacity
0
0 to 3
9999