REMOVING VALVE

1) Shut off the gas and electrical supply.
2) Remove the faceplate, safety screen and
glass door–see detailed instructions in
manual.
3) Remove the logs.
4) Remove the burner/grate assembly by
removing the two screws and then lift the
burner assembly out.
Diagram 1: Remove the left and right screws
and then lift out the burner/grate assembly.
5) Disconnect the inlet gas line.
6) Disconnect the EV1, EV2, and ground wires
from the valve - as shown below.
EV1
7) Disconnect cable from pressure regulator motor.
8) Disconnect spark electrode and sensing
electrode wire from DFC board.
9) Remove the rear log stand by removing the
2 screws.
10) Remove the 10 screws securing the
valve tray assembly in place (Diagram
2) and then lift the entire assembly out
(Diagram 3).
screws
Diagram 2: Rear Log Stand and
11) Lift out valve tray.
12) Replace with a new a valve tray assembly
and reverse steps 9 - 1.
Ground
EV2
screws
Rear Log Stand
Valve Tray Assembly
Valve Tray Assembly