Framing With Vignette Faceplate; Framing With Vignette Faceplate & Finishing Trim Finished Flush; Framing With Louvers And Safety Screen - Regency P36E-NG10 Owners & Installation Manual

Panorama p36e zero clearance direct vent gas fireplace
Table of Contents

Advertisement

installation
|
14
FRAMING WITH
VIGNETTE FACEPLATE/VIGNETTE
FINISHING TRIM, STEPPED FINISH
Frame in the enclosure for the unit with framing
material. The framed opening is 40-3/4" high x
36-1/4" wide x 12-3/4" deep (1036mm high x
921mm wide x 324mm deep).
Diagram 1
*Minimum Height
to Combustible
Steel stud on edge
C
A
Diagram 2
All other framing may be of combustible
materials, i.e. 2 x 4, 2 x 6
Vignette Framing Dimensions
A
B
C
36-1/4"
40-3/4"
12-3/4"
921mm
1036mm
324mm
* 'D' is Minimum height to combustible materials
including the Minimum 2" (51mm) Top clearance
to the Horizontal Vent.
NOTE: If using the optional Vignette finishing trim, this can be installed as a 3-sided or 4 sided finish trim. If choosing to use this as a 4 sided finish trim the
framing would need to be increased by 1-1/4" inches minimum in order for this to fit. This must be to the finished floor. (Eg: Diagram 2 B= 40-3/4" framing
height + 1-1/4". Bottom of 4-sided finishing trim +1/2 thick finished floor = 42-1/2".
If choosing to finish this appliance as a flush finish (Diagram 4) when using the Vignette along with the Vignette finishing trim, see installation
instructions in this manual for details on installation,framing and finishing.
14 |
P36E-10 Zero Clearance Direct Vent Gas Fireplace
FRAMING WITH VIGNETTE
FACEPLATE & FINISHING TRIM
FINISHED FLUSH
Frame in the enclosure for the unit with framing
material. The framed opening is 41-5/8" high x
38" wide x 14-3/4" deep (1057mm high x 965mm
wide x 375mm deep).
Material
Steel stud on edge
D
All other framing may be of combustible
materials, i.e. 2 x 4, 2 x 6
Vignette + Finishing Trim - Flush Finish
Framing Dimensions
D
A
46"*
38"
1168mm*
965mm
* 'D' is Minimum height to combustible materials
including the Minimum 2" (51mm) Top clearance
to the Horizontal Vent.
Diagram 3
*Minimum Height
to Combustible
Material
C
A
Diagram 4
B
C
D
41-5/8"
14-3/4"
46"*
1057mm
375mm
1168mm*
FRAMING WITH
LOUVERS AND SAFETY SCREEN
Frame in the enclosure for the unit with framing
material. The framed opening is 36-1/4" high
x 36-1/4" wide x 12-3/4" deep (921mm high x
921mm wide x 324mm deep).
Diagram 5
D
Diagram 6
Safety Screen + Louvers
Framing Dimensions
A
B
36-1/4"
36-1/4"
921mm
921mm
* 'D' is Minimum height to combustible materials
including the Minimum 2" (51mm) Top clearance
to the Horizontal Vent.
C
D
12-3/4"
46"*
324mm
1168mm*

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36e-lp10