Topping Off The Oil - KAESER CSD 75 Service Manual

Screw compressor
Table of Contents

Advertisement

9.11

Topping off the oil

The oil level indicator (9) of machines in operation should be checked weekly. The machine
should be topped off with oil as soon as the minimum level (1) (border of green and red) is
reached.
Attention!
1 Lowest oil level
 Remove cover panel (3, siee chapter 9.2).
 Check the oil level when the compressor is running.
 Stop the compressor package under full load (see chapter 8.4).
 Venting the compressor package (see chapter 9.9).
The machine may only be operated when the oil level indicator is in the
green zone.
1
2 Optimum oil level
Lock the main disconnect in the "off" position in accordance with ap-
plicable lock out/tag out procedures (example: OSHA CFR 29
§ 1910.147) to ensure the compressor does not restart.
Before opening or removing pressurized components (pipes, hoses,
tanks, etc.) it is imperative that the compressor package is completely
depressurized.
Maintenance
2
3 Highest oil level
3
9 --- 42

Hide quick links:

Advertisement

Table of Contents
loading