Supermicro SuperServer User Manual page 49

Hide thumbs Also See for SuperServer:
Table of Contents

Advertisement

Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below
for pin definitions.
Fan Fail and UID LED
Connect an LED cable to pins 7 and 8 of the front control panel to use the Overheat/Fan
Fail LED connections. The LED on pin 8 provides warnings of overheat or fan failure. Refer
to the tables below for pin definitions.
OH/Fan Fail Indicator
Status
State
Definition
Off
Normal
On
Overheat
Flashing
Fan Fail
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins
11 and 12 of JF1, and LAN port 2 is on pins 9 and 10. Attach the NIC LED cables here to
display network activity. Refer to the table below for pin definitions.
Chapter 4: Motherboard Connections
Power Fail LED
Pin Definitions (JF1)
Pin#
Definition
5
3.3V
6
PWR Supply Fail
LAN1/LAN2 LED
Pin Definitions (JF1)
Pin# Definition
9
NIC 2 Activity LED
11
NIC 1 Activity LED
49
OH/Fan Fail LED
Pin Definitions (JF1)
Pin# Definition
7
Blue LED
8
OH/Fan Fail LED

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1029p-wtrt

Table of Contents