MAiNTeNANCe

CleANiNG The filTeRS
before every use, you should inspect the air filters
in the turbine to see if it is excessively dirty. If it is
dirty, follow these steps to replace it.
Attention
Never operate your unit without the air filters. dirt
could be sucked in and interfere with the function
of the unit.
1.
unplug the spray gun. push the snap levers (a) on the two
turbine covers and remove them.
remove the dirty filters and replace with new ones. the
smooth side of the air filter must be placed toward the turbine.
Secure the covers back onto the turbine.
CleANiNG The AiR vAlve TUBe
i
If spray material ever enters the air valve tube,
follow the steps below.
1.
pull the air tube (a) at the top from the nozzle. Screw off the
valve cover (b).
remove the valve seal (c). Clean all the parts carefully. make
sure to remove any material from valve seal housing area (d).
the air tube and valve seal (c) are only solvent-
resistant to a limited extent. do not immerse in
solvent, only wipe.
Attention
2.
place the valve seal (c) in the valve cover (b) with the pin
facing into the tube. Installing the valve seal into the valve
cover will be much easier if the valve cover is inverted.
3.
turn the nozzle upside down and screw on the valve cover
(with valve seal inside) from underneath. turning the nozzle
upside down will prevent the valve seal from falling out of the
valve cover during reinstallation.
4.
place the air tube on the valve cover and on the nipple at the
nozzle.