input supervision, backup input, and automatic
switchover, power supply, cables.
AA-120/AA-100:Audio Amplifier provides up to 120 watts
of 25 V
audio power for the AFP-400. The amplifier
RMS
contains an integral chassis for mounting to a CAB-B3/
-B4, -C3/-C4, or -D3/-D4 backbox (consumes one row).
Switch-mode power. Includes audio input and amplified
output supervision, backup input, and automatic
switchover to backup tone. Order the AA-100 for 70.7
V
systems and 100 watts of power.
RMS
VROM-(n): Factory-programmed message for installation
in AMG-1. Provides up to 24 seconds of evacuation
message on nonvolatile memory chip. Choose one of
many standard messages available.
Up to two of these messages may be
installed in one AMG. Includes
VROM, instructions for installation
and operation, and written text of
message.
VRAM-1: Field-programmed memory to be installed in
AMG-1. Provides up to 24
seconds of field-programmable
evacuation message on nonvola-
tile memory chip. Message is
programmed from microphone or
cassette tape. Up to two of these
nonvolatile memory chips may
be installed in one AMG. Includes
VRAM and instructions for installation and operation.
XPIQ: Intelligent transponder designed for multi-channel
applications. See XPIQ data sheet DN-6823.
APS-6R: Auxiliary Power Supply
(expander). Provides up to 6.0
amperes of regulated power for
compatible Notification appliance
circuits. Includes battery input and
transfer relay, and overcurrent
protection. Mounts on one of four
positions on a CHS-4L or CHS-4
chassis. See APS-6R data sheet DN-
5952.
FCPS-24: The FCPS-24 is a remote 6-amp (4-amp
continuous) repeater/power supply. See FCPS-24 data
sheet DN-5132.
FCPS-2456/-2458: Remote six-amp and eight-amp power
supplies. See FCPS-2456/-2458 data sheet DN-6927.
UZC-256: Programmable Universal Zone Coder provides
positive non-interfering successive zone coding.
Microprocessor-controlled, field-programmable from
IBM-compatible PCs (requires programming kit).
See UZC-256 data sheet DN-3404.
LCD-80/LCD-80TM: 80-character, backlit LCD display.
Mounts up to 6,000 ft. from panel. Up to 32 per AFP-
400. See LCD-80, LCD-80TM data sheet DN-3198.
Page 8 of 10 — DN-5262 • 10/31/05
ACS: Annunciator Control Modules ACM-16AT, AEM-16AT,
ACM-32A, and AEM-32A.
See ACS data sheet DN-0524.
AFM: Annunciator Fixed Modules AFM-16A, AFM-16AT,
and AFM-32A. See AFM data sheet DN-0056.
LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-
R32. See LDM data sheet DN-0551.
ACM-8R: Remote Relay Module with eight Form-C
contacts. Can be located up to 6,000 ft. from panel on
four wires. See ACM-8R data sheet DN-3558.
RPT-485: Repeats EIA-485 over twisted pair or converts to
fiber-optic medium. See RPT data sheet DN-4737.
XP: The XP Series Transponder provides conventional
monitor and control points.
See XP data sheet
DN-0759.
CHS-4: Chassis for
mounting up to four
APS-6R.
CHS-4L: Low-profile four-
position Chassis.
Mounts two AA-30
3576vrom.wmf
amplifiers or one AMG-
E and one AA-30.
CHS-4M: Expansion
Chassis. Mounts up to
four modules. Includes CHS-4, MP-1 (Module Dress
Panel), and Expander Ribbon Cable.
DP-1: Blank Dress panel.
Provides dead-front panel for
0740vram.wmf
unused tiers or to cover AA-
30, AA-120, or AMG-E.
CAB-4 Series: The CAB-4
Series cabinets are fabricated from 16-gauge steel with
unique full-front LEXAN®, reverse
silk-screened for durability. The
cabinet assembly consists of two
basic parts: a backbox (SBB-_4),
and a locking door (DR-_4 )that
may hinge right or left. Cabinets are
arranged in four (4) sizes, A through
D (B [two-tier] is pictured at right). A
trim ring option is available for
semi-flush mounting. See CAB-4
Series data sheet DN-6857.
5952cov.wmf
LEXAN® is a registered trademark of GE Plastics, a
subsidiary of General Electric Company.
CAB-400AA: Provides small cabinet for CPU-400 and
MPS-400RB. Use with BE-400AA only. Space for one
(only) output circuit module plus expander.
MPS-400: Power Supply module. The MPS-400 includes
4 Notification Appliance Circuits (NAC) that can
connect four Class A (Style Z) or Class B (Style Y)
circuits. The NAC also can be used for Releasing
applications. Includes four built-in system relays
(alarm, trouble, security, and supervisory).
For BE-400 replacement only. The MPS-400 is
included in the BE kits.
MPS-400RB: MPS-400 PC board only. Less transformers
and mounting chassis.
5262ch4L.wmf
5262dp1.wmf
5871cab3.wmf