Specifications; Ambient Operating Temperature - Siemens SITRANS LR 200 Quick Start Manual

Radar
Hide thumbs Also See for SITRANS LR 200:
Table of Contents

Advertisement

LR-200QS-EN.fm Page 2 Wednesday, March 12, 2003 3:51 PM
SITRANS LR 200
WARNING: Changes or modifications not expressly approved by Siemens
Milltronics could void the user's authority to operate the equipment.
Note:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense
SITRANS LR 200 is to be used only in the manner outlined in this manual, otherwise protection
provided by the equipment may be impaired.
SITRANS LR 200 is a 2-wire loop-powered, continuous level-measuring instrument that utilizes
advanced pulse radar technology at 5.8 GHz (6.3 GHz in the USA). The instrument consists of an
electronic component coupled to the antenna and process connection.

Specifications

For a complete listing, see the SITRANS LR 200 Instruction Manual. For Approvals information,
please refer to the process device tag.
Ambient/Operating Temperature
Note: Process temperature and pressure capabilities are dependent upon information
on the process device tag. The reference drawing listed on the tag can be downloaded
from the Siemens Milltronics Web site at www.siemens-milltronics.com
ambient temperature
(surrounding enclosure volume)
o
o
o
–40
C to 80
C (–40
F to 176
process temperature
o
o
o
–40
C to 80
C (–40
F to 176
Power
Nominal 24 Vdc with 550 Ohm:
• Maximum 30 Vdc
Page EN-2
SITRANS LR 200 – QUICK START MANUAL
o
F)
o
F)
For other configurations see the full manual
• 4 to 20 mA
process device
tag
7ML19985QL81

Advertisement