Test Printout; Printer Malfunction - Vectron HW 90196 User Manual

Table of Contents

Advertisement

Vectron

6.4 Test printout

To process a test printout:
1. Switch on printer with on/off-key.
2. Open casing flap.
3. Press on/off-key and continue pressing it .
4. Close casing flap.
5. Release on/off-key.
A test printout with an extract of supported fonts und printable charactes will be printed. Also informations
about serial number and BIOS- and bootloader number will be given.

6.5 Printer malfunction

Malfunction
Printout is not ejected poperly.
The HW 90195 stops during printing and shows no
more reaction.
Printing does not start.
No message about end of paper reel, printing can
be continued.
All recieved but not yet printed characters are de-
leted after interruption of connection, resp. connec-
tion establishing, by the radio terminal because of
impossible feedback to radio terminal without radio
connection.
© Höft & Wessel AG
Subject to amendment, errors excepted
User manual
Elimination
Check, if paper reel has just been inserted. If so,
take reel out and insert again.
The accu block is almost completely discharged
and HW 90196 stopped printing. Recharge accu
block or insert a recharged accu block.
Read messages in display of terminal.
Open flap of paper reel casing. Clean sensor for
„paper end" by blowing out printing unit.
After establishing a new connection the printout can
be repeated.
HW90195UserMan.doc