1.3.2

1.3.2 EKI-1351, EKI-1352

Ethernet communication compatibility: IEEE802.11b, IEEE802.11g
Protocol: TCP/IP
Interface:
Network: Wireless
Serial: RS-232/422/485
Serial ports: 1/2/4 independent RS-232/422/485 ports
EKI-1351: 1 x RS-232/422/485 port
EKI-1352: 2 x RS-232/422/485 port
Connector
Serial: DB9
Baud rate: 50~ 921kbps
Throughput:
Total throughput up to 1.2M bps
Parity bit: odd, even, none, space, mark
Data bit: 5, 6, 7, 8
Stop bit: 1, 1.5, 2
Data Signals:
Diagnostic LEDs: Power, Status, Ethernet Tx/Rx and Serial Tx/Rx
Utility Software: Integrated auto-detecting configuration and Port mapping utility
Driver Supported: Windows NT/2000/XP/Vista(X86)
Enclosure: Metal with solid DIN rail or panel mounting hardware.
Power requirements: dual unregulated 12~48V with surge protection.
Power consumption: EKI-1351:2W, EKI-1352: 4W
Serial protection: 15KV ESD.
Power protection: 4 KV burst (EFT), EN61000-4-4, 2 KV surge, EN61000-4-5,
Overload 2A/125V Replaceable Fuse
Ethernet protection: Built-in 1.5 KV magnetic isolation.
Operation Temperature: 0~55
Storage Tempaerature:-20~80
Operating Humidity:20~95%(non-condensing)
Storage Humidity:0~95%(non-condensing).
1.4

1.4 Package Check List

EKI serial device server
One RS-232 loopback DB9 tester
Panel mounting bracket
CD-ROM for utility and manual
RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485: Data+, Data-, GND