Reset Adjustment

To adjust reset action (figure 9) turn the knob clockwise to decrease reset time (the minutes per repeat). Turn the
knob counterclockwise to increase the minutes per repeat. Increasing the minutes per repeat provides a slower reset
action.
The reset rate adjustment dial is calibrated in minutes per repeat. By definition, this is the time in minutes required for
the reset action to produce a correction which is equal to the correction produced by proportional control action. This
is, in effect, the time in minutes required for the controller to increase (or decrease) its output pressure by an amount
equal to a proportional increase (or decrease) caused by a change in control conditions.