Jog Operation - Omron SYSDRIVE 3G3SV-B2002-E User Manual

Table of Contents

Advertisement

Note
2-10-4 9-step Speed Change
Item name
Multi-speed frequency command
Multi-function command
Frequency
command
Frequency
command 2
Frequency
command 1
Terminal
Normal and reverse
rotation command
Multi-speed
command 1
Multi-speed
command 2
Multi-speed
command 3
Jog
frequency

2-10-5 Jog Operation

Item name
Jog frequency
1. The output voltage will not exceed the upper limit if the output
voltage limitter function is used. To increase the output voltage
ignoring the upper limit, do not use the output voltage limitter
function. For details refer to 2-10-25 Output Voltage Limitter .
2. If an excessively large value is set in low-speed area (3 Hz or
less), motor overheating or inverter malfunction may occur.
No. 13 to No. 17, No. 41 to
No. 44
No. 32 and No. 33
Up to 9 steps of speeds can be set using signals from external ter-
minals 5 to 8. This eliminates the need for an analog signal thereby
enabling operation by simplified external control. See the following
example.
Set according to run specifications.
Frequency
command 6
Frequency
command 5
Frequency
command 4
Frequency
command 3
No. 41
No.16
No. 15
No. 14
No.13
Closed
Closed
Open
Closed
Open
Closed
Open
Open
No. 17
Select the jog mode (connect terminals 9 to 7) and input the start
signal. Jog operation starts.
Depressing the
same operation.
Constant to be set
Frequency
command 7
Frequency
command 8
No. 44
No. 43
No. 42
Closed
Constant to be set
key on the digital operator performs the
JOG
Section 2-10
Factory preset
See page 39 and 42.
See page 41.
Jog
frequency No. 17
Time
Open
For 9-step speed
No. 32 = 1
No. 33 = 3
Factory preset
6.0 Hz