Function/Constant List - Omron SYSDRIVE 3G3SV-B2002-E User Manual

Table of Contents

Advertisement

2-9

Function/Constant List

First Functions (Constant Nos. 0 to 19)
Function
No.
Name
Password
0
Password
setting
Constant
write-in
prohibit
Constant
group se-
lection
Fault con-
tents clear
Constant
initializa-
tion
Operation
1
Run signal
method
selection 1
selection
Stopping
method
selection
Output
Output volt-
voltage li-
age limitter
mitter
V/f char-
2
Maximum
acteristic
frequency
setting
3
Maximum
voltage
4
Maximum
voltage fre-
quency
(base fre-
quency)
5
Intermediate
output fre-
quency
6
Intermediate
output fre-
quency volt-
age
Description
0: Password (No. 00) setting/reading and
first function (constant Nos. 1 to 19)
reading possible
1: First function (constant Nos. 0 to 19) set-
ting/reading possible
2: First and second function (constant Nos.
0 to 29) setting/reading possible
3: First, second and third function (constant
Nos. 0 to 59) setting/reading possible
6: Fault record clear
8: Initialize (multifunction terminal: initial
value setting)
9: Initialize (3-wire sequence)
1st digit = 0: Main frequency reference-ex-
ternal terminals 11 and 13 in-
puts
1: Main frequency reference-op-
erator Fxxxx
2nd digit = 0: Run by external terminal run
command
1: Run by operator run com-
mand
3rd digit = 0: Deceleration to a stop
1: Coasting to a stop
4th digit = 0: With output voltage limitter
1: Without output voltage limitter
Setting unit: 0.1 Hz, setting range: 50.0 to
400.0 Hz
Setting unit: 0.1 V, setting range: 0.1 to
255.0 V
Setting unit: 0.1 Hz, setting range: 0.1 to
400.0 Hz
Setting unit: 0.1 Hz, setting range: 0.1 to
400.0 Hz
Setting unit: 0.1 V, setting range: 0.1 to
255.0 V
Section 2-9
Initial
User
See
setting
set
page
values
1
43
0000
44
56
60.0 Hz
44
200.0 V
44
60.0 Hz
44
1.5 Hz
44
12.0 V
44

Hide quick links: