General data
Table 5 - RTUD - R134a (Continued)
Indicative performances
Cooling Capacity (1)
Total Power input in cooling (1)
Compressor
Compressor Number per Circuit
Type
Model
Evaporator
Quantity
Type
Evaporator model
Evaporator Water Content volume
Two pass evaporator
Evap. Water Flow rate - Minimum
(2)
Evap. Water Flow rate - Maximum
(2)
Nominal water connection size
(Grooved coupling)
Three pass evaporator
Evap. Water Flow rate - Minimum
(2)
Evap. Water Flow rate - Maximum
(2)
Nominal water connection size
(Grooved coupling)
Condenser
Discharge Connection Diameter
Liquid Connection Diameter
Dimensions (3)
Unit Length
Unit Width
Unit Height
Weights (4)
Shipping Weight
Operating Weight
System data (5)
Nb of refrigerant circuit
Minimum cooling load %
Standard unit
R134a refrigerant content
Circuit1 / Circuit 2
Oil charge Circuit1 / Circuit 2 (6)
POE Oil type
Maximum R134a Refrigerant charge
in the system
(1) Indicative performance at Evaporator water temperature: 12°C / 7°C - Condenser water temperature 30°C/35°C (RTWD equivalent conditions) -
for detailed condenser condition and units performances consult order write up.
(2) Not applicable for Glycol application - see tables with Minimum Flow with Glycol.
(3) These dimensions are the maximum for a specifi c size, they may vary from one confi guration to another within a same size. For accurate
dimensions of a specifi c confi guration, refer to relevant submittal drawings.
(4) All weights +/-5% and are the maximum for each size and may vary from one confi guration to another for the same size (add 62kg for unit with
acoustic package) and refer to relevant drawing for a specifi c confi guration.
(5) System data are indicative and subject to change without notice. Please refer to unit nameplate data.
(6) RTUD unit is shipped w/o oil - oil must be ordered separatly as it is not coming with unit.
16
RTUD
RTUD
140
160
(kW)
474
519
(kW)
120
130
#
1/1
1/1
M1/M2
M2/M2
#
1
1
E3AM2
E3BM2
(l)
77.0
85.0
(l/s)
9.5
10.7
(l/s)
34.9
39.1
(in) -
5 1"
5 1"
(mm)
(139.7 mm)
(139.7 mm)
(139.7 mm)
(l/s)
6.4
7.13
(l/s)
23.3
26.12
(in) -
411
411
(114.3 mm)
(114.3 mm)
(114.3 mm)
(mm)
2"5/8 /
2"5/8 /
(in)
2"5/8
3"1/8
1"3/8 /
1"3/8 /
(in)
1"3/8
1"3/8
(mm)
3400
3400
(mm)
1280
1280
(mm)
1950
1950
(kg)
3087
3225
(kg)
3164
3310
#
2
2
%
30
30
(kg)
30/30
30/30
(l)
177/177
173/173
RTUD
RTUD
RTUD
170
180
190
584
569
637
157
145
171
1/1
1/1
1/1
Screw
N1/N1
M2/N1
N1/N2
1
1
1
Flooded shell and tube heat exchanger
E3BM1
E3AMJ
E3BM1
75.5
91.0
84.0
9.3
11.7
10.6
34.1
43
38.9
5 1"
5 1"
5 1"
(139.7 mm)
(139.7 mm)
6.2
7.82
7.1
22.7
28.64
25.9
411
411
411
(114.3 mm)
(114.3 mm)
3"1/8 /
2"5/8 /
3"1/8 /
3"1/8
2"5/8
3"1/8
1"3/8 /
1"3/8 /
1"3/8 /
1"3/8
1"3/8
1"5/8
3490
3400
3490
1310
1280
1310
1970
1950
1970
3346
3393
3345
3421
3485
3429
2
2
2
30
30
30
30/30
30/30
30/30
OIL048E or OIL023E
170/170
RTUD
RTUD
RTUD
200
220
250
637
682
748
171
175
190
1/1
1/1
1/1
N1/N1
N1/N2
N2/N2
1
1
1
E5AM2
E5AM1
E5AMJ
108.0
113.3
120.3
13.3
14.1
15.1
48.6
51.5
55.3
6"
6"
6"
(168.3 mm)
(168.3 mm)
(168.3 mm)
8.83
9.3
10.1
32.43
24.3
36.9
411
411
411
(114.3 mm)
(114.3 mm)
(114.3 mm)
3"1/8 /
3"1/8 /
3"1/8 /
3"1/8
3"1/8
3"1/8
1"3/8 /
1"3/8 /
1"5/8 /
1"3/8
1"5/8
1"5/8
3490
3490
3490
1310
1310
1310
2010
2010
2010
3476
3510
3525
3584
3623
3645
2
2
2
30
30
30
30/30
30/30
30/30
177/177
191/191
189/189
RLC-SVX14H-GB