Power Supply
CAUTION: Use only the power adapter supplied with the Dome E3 display unit;
Ault MW122KA1223F52.
Category
Power input
requirements
Power output
requirements
Physical
Reliability
Characteristic item
Display
Backlight
Environment
Characteristic item
EMI shielding
Temperature
Humidity
34 | Dome Display
Characteristic Item
Voltage selection
Voltage
Current
Frequency
Voltage
Current
Size
Weight
Specification
MTBF >50,000 hours
MTBF 50,000 hours to 50% brightness with backlight on continuously
operating
storage
operating
storage
Specification
Auto-ranging
100 – 240V AC
2.0 A
50 to 60 Hz
±
12 V DC
5%
10.0 A (120 W)
228.6 mm x 76.2 mm x 50.8 mm
(9 in x 3 in x 2 in)
1.3 kg (2.75 lb)
Specification
No emission of low-level radiation
0° C to 40° C
-10° to 60° C
10% to 80% Relative Humidity
(non-condensing)
5% to 90% Relative Humidity
(non-condensing)