Supplement; Technical Data - Vega VEGABAR 14 Operating Instructions Manual

Hide thumbs Also See for VEGABAR 14:
Table of Contents

Advertisement

9 Supplement

9.1 Technical data

General data
Parameter, pressure
Measuring principle
Communication interface
Materials and weights
Materials, wetted parts
Process fitting
-
Diaphragm
-
Measuring cell seal
-
Materials, non-wetted parts
Electronics housing
-
Materials, non-wetted parts, version with plug connector ISO 4400
Contact, housing plug
-
Cover screw
-
Contact surface
-
Plug seal
-
Materials, non-wetted parts, version with plug connector M12 x 1
Contact support
-
Contacts
-
Plug seal
-
Materials, non-wetted parts, connection cable with plug connector M12 x 1 (optional)
Grip body, plug connector
-
Compression nut
-
Cable/wire insulation
-
Materials, non-wetted parts, verson with cable outlet
Cable gland
-
Cable
-
Ohmic contact
Torque max.
2)
Weight approx.
Output variable
Output signal
VEGABAR 14
Gauge pressure, absolute pressure, vacuum
Ceramic-capacitive, dry measuring cell
None
316L, PVDF
sapphire ceramic
FKM (VP2/A), EPDM (A+P 75.5/KW75F)
brass, nickel-plated
PA
StSt
Sn
Silicone
PA
CuZn, nickel layer and 0.8 µm gold-plated
FKM
PA
Zinc die casting
PVC
PA
PE
Between ground terminal, housing and process
fitting
50 Nm (36.88 lbf ft)
0.25 kg (0.55 lbs)
4 ... 20 mA
With material process fitting 316L.
2)
9 Supplement
®
(99.9 % oxide ceramic)
21