Configuration, programming
4.7 Setting up FTP communication
Requirements in the CPU configuration and programming
Use the following settings to allow FTP access:
● In the CPU configuration in "Protection & Security > Connection mechanisms":
Disable the option "Access via PUT/GET communication...".
● As file DBs create data blocks of the type "Array of byte".
● For all data blocks being used as file DBs, disable the "Optimized block access" attribute.
S7-1500 CP as FTP server
The functionality described here allows you to transfer data in the form of files to or from an
S7-1500 station using FTP commands. At the same time, the conventional FTP commands
for reading, writing and managing files can also be used.
Access to the following data of the S7-1500 is possible:
● RAM of the CP
Name of the directory:
/ram
● Data blocks of the CPU
Name of the directory:
/cpu1 / DBx
"DBx" is the name of the relevant data block e.g. DB10.
● SIMATIC memory card of the CPU
The function is supported as of CP firmware V2.0 and CPU firmware V2.0.
Name of the directory:
/mmc_cpu1
Access to the following folders of the SIMATIC memory card is possible:
– /DATALOGS
– /RECIPES
Note
FTP access to the SIMATIC memory card of the CPU: CPU STOP possible
Note that the cards have a limited capacity If the memory space of the SIMATIC memory
card is completely occupied due to storage of large amounts of data, the CPU changes to
STOP.
• Use a card with adequate storage capacity.
• Avoid writing large amounts of data often to the SIMATIC memory card using FTP.
50
Directory for log files
Directory for recipe files
Operating Instructions, 05/2017, C79000-G8976-C289-07
CP 1543-1