Dealing with comfort disruption

Operating mode "Add. heat only"

In the event of malfunctions that cause a low indoor temper-
ature, you can normally activate "Add. heat only" in ACVM
270, which means that heating only occurs with the immer-
sion heater.
Activate the mode by holding in the operating mode button
for 7 seconds.
Note that this is only a temporary solution, as heating with
the immersion heater does not make any savings.

Emergency mode

Emergency mode is activated by setting the switch to "
". It is used when the control system and thereby oper-
ating mode "Add. heat only" do not function as they should.
Emergency mode is activated by setting switch (SF1) to "
".
The following applies in emergency mode:
The front panel is not lit and the control computer in
ACVM 270 is not connected.
AMS 10 is off and only the circulation pump and immer-
sion heater in ACVM 270 are active.
An electrical step of 4 kW is connected. The immersion
heater is controlled by a separate thermostat (BT30).
The automatic heating control system is not operational,
so manual shunt operation is required. Call installer.
14