Control
Control Methods
General
Operating Temperature / RH
Storage Temperature / RH
Power Supply
Power Consumption
ESD Protection
Dimension (W × H × D)
Weight
Certification
CABLE SPECIFICATIONS
To ensure best performance of DUX-SRX, please use stright-through Category cables
wired to T568B standard and a Transmitter device which also supports 100-meter
transmission.
Cable Type
Cat5e/6
Cat6a/7
USER MANUAL - DUX-SRX
100-METER 4K HDBASET SCALING RECEIVER
Telnet, RS232, IR
32°F ~ 113°F (0°C ~ 45°C)
10% ~ 90%, non-condensing
-4°F ~ 140°F (-20°C ~ 70°C)
10% ~ 90%, non-condensing
12 VDC 3.0A
16.4 W (Max.)
Human-body model:
•
±8 kV (Air-gap discharge)
•
±4 kV (Contact discharge)
234.4 mm × 25 mm × 143 mm
0.9 kg
CE, FCC
Range
Supported Video
100m/328ft
1080p@60Hz 36bit
1080p@60Hz 3D
70m/230ft
4K@30Hz YUV4:4:4
4K@60Hz YUV4:2:0
1080p@60Hz 36bit
1080p@60Hz 48bit
100m/328ft
1080p@60Hz 3D
4K@30Hz YUV4:4:4
4K@60Hz YUV4:2:0