Supermicro SC815 series User Manual

Supermicro SC815 series User Manual

Hide thumbs Also See for SC815 series:
Table of Contents

Advertisement

Проконсультироваться и купить данное оборудование вы можете в компании «АНД-Системс»
адрес: 125480, г.Москва, ул.Туристская, д.33/1; site: https://andpro.ru тел: +7 (495) 545-4870 email: info@andpro.ru
SC815T-563(CB)(UB)
SC815TQ-720(CB)(UB)
SC815TQ-710(B)
SC815TQ-R706WB
SC815TQ-R600
(CB)(UB)(WB)
SC815TQ-R500
(CB)(UB)(WB)
SC815TQC-R605
SC815S-R650C(V)(B)
SC815TQ-R650U(V)(B)
При обращении используйте промокод AND-PDF и получите скидку.
SC815 Chassis Series
(CB)(WB)
USER'S MANUAL
REAR VIEW
FRONT VIEW
SC815T-330(CB)(UB)
SC815TQ-710U(B)
SC815TQ-710C(B)
SC815TQC-R706
SC815TQC-R504
SC815TQ-R650C(V)(B)
SC815TQ-R654(CB)
1.1b
SC815TQ-R700
(CB)(UB)(WB)
SC815TQ-R563
(CB)(UB)
(CB)(WB)
(CB)(WB)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC815 series and is the answer not in the manual?

Questions and answers

Summary of Contents for Supermicro SC815 series

  • Page 1 Проконсультироваться и купить данное оборудование вы можете в компании «АНД-Системс» адрес: 125480, г.Москва, ул.Туристская, д.33/1; site: https://andpro.ru тел: +7 (495) 545-4870 email: info@andpro.ru При обращении используйте промокод AND-PDF и получите скидку. REAR VIEW SC815 Chassis Series FRONT VIEW SC815T-563(CB)(UB) SC815T-330(CB)(UB) SC815TQ-720(CB)(UB) SC815TQ-710U(B) SC815TQ-710(B)
  • Page 2 This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a This manual is written for professional system integrators and PC technicians. It license.
  • Page 3: Table Of Contents

    Chapter 2: Standardized Warning Statements for AC/DC Systems Shipping List ....................1-1 This chapter lists warnings, precautions, and system safety. You should thoroughly Contacting Supermicro ..................1-3 familiarize yourself with this chapter for a general overview of safety precautions Returning Merchandise for Service..............1-4 that should be followed before installing and servicing this chassis.
  • Page 4 SC815 Chassis Manual Preface Appendix A SC815 Power Supply Specifications Control Panel LEDs ..................4-3 Drive Carrier LEDs ..................4-5 Appendix B BPN-SAS-815TQ Backplane Specifications Power Supply LEDs and Overheat Indicators ..........4-5 Appendix C BPN-SAS3-815TQ Backplane Specifications 450W and 650W Power Supplies ..............4-5 All Other Power Supplies ................
  • Page 5 SC815 Chassis Manual Notes viii...
  • Page 6: Chapter 1 Introduction Overview

    Chapter 1 Introduction Overview Supermicro’s SC815 1U chassis features a unique and highly-optimized design. The chassis is equipped with a high efficiency power supply. High performance fans provide ample optimized cooling for FB-DIMM memory modules and four hot-swap drive bays offer maximum storage capacity in a 1U form factor.
  • Page 7: Contacting Supermicro

    UB: 1 FH UIO: Redundant (Gold (CB)(UB) Fax: +1 (408) 503-8008 1x FF, 1x LP Level) Email: marketing@supermicro.com (General Information) CB: 1x FF UB: 1 FH UIO: support@supermicro.com (Technical Support) 500W Redundant SC815TQ-R500 4x SAS/SATA 1x FF, 1x LP CB)(UB)(WB)
  • Page 8: Returning Merchandise For Service

    For faster service, RMA authorizations may be requested online (http://www. supermicro.com/support/rma/). Whenever possible, repack the chassis in the original Supermicro carton, using the original packaging material. If these are no longer available, be sure to pack the chassis securely, using packaging material to surround the chassis so that it does not shift within the carton and become damaged during shipping.
  • Page 9: Chapter 2 Standardized Warning Statements For Ac/Dc Systems

    Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger.
  • Page 10 SC815 Chassis Manual Warning Statements for AC Systems Warnung ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ WICHTIGE SICHERHEITSHINWEISE ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬ ، ‫ك‬ ‫هعذات‬ ‫تعول على أي‬ ‫قبل أى‬ Dieses Warnsymbol bedeutet Gefahr.
  • Page 11: Installation Instructions

    SC815 Chassis Manual Chapter 2: Warning Statements for AC/DC Systems Installation Instructions Circuit Breaker Warning! Warning! This product relies on the building's installation for short-circuit (overcurrent) Read the installation instructions before connecting the system to the power source. protection. Ensure that the protective device is rated not greater than: 60VDC, 20 A. 設置手順書...
  • Page 12: Power Disconnection Warning

    SC815 Chassis Manual Chapter 2: Warning Statements for AC/DC Systems ¡Advertencia! 경고! El sistema debe ser disconnected de todas las fuentes de energía y del cable 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso 의존합니다.
  • Page 13: Equipment Installation

    SC815 Chassis Manual Chapter 2: Warning Statements for AC/DC Systems Equipment Installation Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door Warning! geschoold en gekwalificeerd personeel. Only trained and qualified personnel should be allowed to install, replace, or service Restricted Area this equipment.
  • Page 14: Battery Handling

    SC815 Chassis Manual Chapter 2: Warning Statements for AC/DC Systems Warnung ‫אזור עם גישה מוגבלת‬ Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. !‫אזהרה‬ Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. ‫יש...
  • Page 15: Redundant Power Supplies

    SC815 Chassis Manual Chapter 2: Warning Statements for AC/DC Systems Redundant Power Supplies ‫امداد الطاقة‬ ‫بوحدات‬ ‫عدة اتصاالت‬ ‫جهاز‬ ‫ال‬ ‫يكون لهذا‬ ‫قد‬ ‫الكهرباء‬ ‫عن‬ ‫وحدة‬ ‫ال‬ ‫لعسل‬ ‫كافة االتصاالت‬ ‫يجب إزالة‬ 경고! Warning! This unit might have more than one power supply connection. All connections must 이...
  • Page 16: Comply With Local And National Electrical Codes

    SC815 Chassis Manual Chapter 2: Warning Statements for AC/DC Systems Attention ‫מתח בפנל האחורי‬ L'équipement doit être installé conformément aux normes électriques nationales et locales. !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ ‫תיאום חוקי החשמל הארצי‬ .‫העבודה‬...
  • Page 17: Hot Swap Fan Warning

    SC815 Chassis Manual Chapter 2: Warning Statements for AC/DC Systems ¡Advertencia! 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 Al deshacerse por completo de este producto debe seguir todas las leyes y 物品太靠近風扇。 reglamentos nacionales. Warnung Attention Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis La mise au rebut ou le recyclage de ce produit sont généralement soumis à...
  • Page 18: Dc Power Supply

    SC815 Chassis Manual Chapter 2: Warning Statements for AC/DC Systems DC Power Supply Attention Quand des fils torsadés sont nécessaires, utiliser des douilles terminales homologuées telles que celles à circuit fermé ou du type à plage ouverte avec Warning! cosses rebroussées. Ces douilles terminales doivent être de la taille qui convient When stranded wiring is required, use approved wiring terminations, such as aux fils et doivent être refermées sur la gaine isolante et sur le conducteur.
  • Page 19: Dc Power Disconnection

    SC815 Chassis Manual Chapter 2: Warning Statements for AC/DC Systems DC Power Disconnection 주의! Warning! 다음 절차들을 수행하기 전에, 전원이 DC회로로부터 제거되었는지를 확인해 Before performing any of the following procedures, ensure that power is removed 주십시오. from the DC circuit. 警告...
  • Page 20 SC815 Chassis Manual ¡Advertencia! Puede haber energía o voltaje peligrosos en los terminales eléctricos de CC. Reemplace siempre la cubierta cuando no estén utilizándose los terminales. Asegúrese de que no haya acceso a conductores descubiertos cuando la cubierta esté colocada. Attention Le voltage ou l'énergie électrique des terminaux à...
  • Page 21: Chapter 3 Chassis Components

    Chassis may include one slim CD-ROM bay and/or four hard drive bays. Most chassis models include a DVD-ROM. Hard drives must be purchased separately. For the latest shipping lists, visit our website at: www.supermicro.com. This chassis accepts a 1U backplane, four fans (with an optional fifth fan) and one (sometimes two) power supplies.
  • Page 22: Power Supply

    Supermicro Authorized Distributors / System Integrators/Resellers. A list of Supermicro Authorized Distributors/System Integra- tors/Reseller can be found at: www.supermicro.com. Click the Where to Buy link.
  • Page 23: Chapter 4 System Interface

    Chapter 4: System Interface Chapter 4 System Interface Overview There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components.
  • Page 24: Control Panel Buttons

    SC815 Chassis Manual Chapter 4: System Interface Control Panel LEDs Control Panel Buttons The control panel located on the front of the SC815 chassis has five LEDs. These There may be up to three push-buttons located on the front of the chassis. These LEDs provide you with critical information related to different parts of the system.
  • Page 25: Drive Carrier Leds

    SC815 Chassis Manual Chapter 4: System Interface Drive Carrier LEDs Your chassis supports either SAS or SATA, SAS/SATA Drives Information LED: Information LED Each SAS/SATA drive carrier has two LEDs. • Status Description Green: Each Serial ATA drive carrier has a green LED. When illuminated, this An overheat condition has occured.
  • Page 26: All Other Power Supplies

    Some backplanes allow the overheat temperature to be set at 45, 50, or 55 by changing a jumper setting. For more information, download the backplane user manual at www.supermicro.com. To access the manuals on the Website, click sup- port, and then click the manuals link.
  • Page 27: Chapter 5 Chassis Setup And Maintenance

    Chapter 5: Chassis Setup and Maintenance Chapter 5 Chassis Setup and Maintenance Overview This chapter covers the steps required to install components and perform mainte- nance on the chassis. The only tool you will need to install components and perform maintenance is a Phillips screwdriver.
  • Page 28: Removing The Chassis Cover And Front Bezel

    SC815 Chassis Manual Chapter 5: Chassis Setup and Maintenance Removing the Chassis Cover and Front Bezel Front Bezel Release Knob Remove this screw (if necessary) Release Tab Bezel pins Bezel Lock Figure 5-2. Removing the Front Bezel Figure 5-1. Removing the Chassis Cover The Front Bezel (Optional) Removing the Chassis Cover If your system has an optional front bezel attached to the chassis, you must remove...
  • Page 29: Installing Hard Drives

    SC815 Chassis Manual Chapter 5: Chassis Setup and Maintenance Installing Hard Drives Dummy Drive Drive Tray Figure 5-4. Chassis Drive Carrier The drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airflow for the drive bays.
  • Page 30: Installing The Dvd Drive

    SC815 Chassis Manual Chapter 5: Chassis Setup and Maintenance Installing the DVD Drive SAS/SATA Hard Drive Drive Tray Figure 5-6. Removing the Hard Drive From the Carrier 3. Install a new drive into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier.
  • Page 31: Installing The Motherboard

    SC815 Chassis Manual Chapter 5: Chassis Setup and Maintenance Installing the Motherboard Installing the Motherboard 1. Review the documentation that came with your motherboard. Become famil- iar with component placement, requirements, and precautions. 2. Power down the system and remove the power cord from the rear of the power supply.
  • Page 32: Expansion Card Setup

    N o t e : Yo u m u s t u s e a r i s e r c a r d t o i n s t a l l e x p a n s i o n c a r d s into any SC815 chassis. Riser cards are sold separately. For the lat- est compatibility and performance information, visit our website at: http://www.supermicro.com. Figure 5-12. Chassis with a Riser Card "C" Model Chassis: One Full-Height, Full-Length PCI Slot...
  • Page 33: Installing The Air Shroud

    SC815 Chassis Manual Chapter 5: Chassis Setup and Maintenance Installing the Air Shroud Installing the Air Shroud 1. Power down the system and remove the power cord from the rear of the power supply. Remove both power cords if your system includes a redundant power supply.
  • Page 34: System Fans

    SC815 Chassis Manual Chapter 5: Chassis Setup and Maintenance System Fans Figure 5-15. Chassis Fans (Note additional fan options) Figure 5-14. System Fan The SC815 chassis includes four pre-installed fans. One or two extra slots are available so that. additional fans may be added. Four heavy duty fans provide cooling for the chassis.
  • Page 35: Power Supply

    A power supply failure is indicated by a flashing red (0.25Hz) LED indicator.Replacement power supply units can be ordered directly from Supermicro (see contact information in the Preface). As there is only one power supply unit in the SC815 Chassis, power must be completely removed from the Release Tab server before removing and replacing the power supply unit for whatever reason.
  • Page 36: Routing The I C Cables

    SC815 Chassis Manual Routing the I C Cables It is necessary to correctly route the I C cables to avoid interference due to noise on the I C lines. Using tie wraps, secure the I C cables to the large black power switch- ing cable to keep it close to the power supply and away from the motherboard.
  • Page 37: Chapter 6 Rack Installation

    Chapter 6 Rack Installation Chapter 6 Rack Installation Overview This chapter provides a quick setup checklist to get your chassis up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. Unpacking the System You should inspect the box the chassis was shipped in and note if it was damaged in any way.
  • Page 38: Rack Precautions

    SC815 Chassis Manual Chapter 6 Rack Installation Rack Precautions environment compatible with the manufacturer’s maximum rated ambient tempera- • ture (Tmra). Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. Reduced Airflow •...
  • Page 39: Identifying The Sections Of The Rack Rails

    SC815 Chassis Manual Chapter 6 Rack Installation Rack Mounting Instructions This section provides information on installing the SC815 chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the instal- lation instructions that came with the rack unit you are using.
  • Page 40: Outer Rack Rails

    SC815 Chassis Manual Chapter 6 Rack Installation Secure to the Front of the Rack Secure to the Rear of the Rack Attach Outer Racks together Figure 6-3. Assembling the Outer Rails Outer Rack Rails Outer rails attach to the server rack and hold the server in place. The outer rails for the SC815 chassis extend between 30 inches and 33 inches.
  • Page 41 SC815 Chassis Manual Figure 6-5. Installing into an Open Rack Note: figures are for illustrative purposes only. Always install servers into racks from the bottom up. Installing the Chassis into a Mid-Mount Position (Telco) Rack 1. Use the two L-shaped brackets on either side of the chassis (four total). 2.
  • Page 42 Appendix A: Power Supply Specifications Appendix A SC815 Power Supply Specifications This appendix lists power supply specifications for your chassis system. Power Supply Specifications 750W 710W/ 700W 700W/ 720W (Redundant) (Redundant) PWS- PWS- PWS- PWS- MFR Part # PWS-504P-1R 721P-1R 711-1R 704P-1R 702A-IR...
  • Page 43 SC815 Chassis Manual Power Supply Specifications 650W/PDB 560W (Redun- 600W 560W 330W (C Models) dant) PWS- PWS-651- PWS-605P- PWS-561- PWS-333- MFR Part # 561- 1H20 1H20 100 - 240V 100-240 100 - 240V 100 - 240V Rated AC Volt- 50 - V, 50-60 50 - 60Hz 50 - 60Hz...
  • Page 44 Appendix B: BPN-SAS-815TQ Backplane Specifications Appendix B BPN-SAS-815TQ Backplane Specifications To avoid personal injury and property damage, carefully follow all the safety steps listed below when accessing your system or handling the components. B-1 ESD Safety Guidelines Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent dam- age to your system, it is important to handle it very carefully.
  • Page 45 This manual reflects BPN-SAS-815TQ Revision 1.00, the most current release avail- SAS Ports able at the time of publication. Always refer to the Supermicro website at www.su- permicro.com for the latest updates, compatible parts and supported configurations. JTAG...
  • Page 46 SC815 Chassis Manual Appendix B: BPN-SAS-815TQ Backplane Specifications B-6 Front Connector and Pin Definitions 6. Sideband Headers Sideband Headers The sideband headers are designated JP51. 1. Backplane Main Power Connectors Backplane Pin # Definition Pin # Definition For SES-2 to work properly, you must connect Main Power The 4-pin connectors, designated JP10 provide Backplane...
  • Page 47 SC815 Chassis Manual Appendix B: BPN-SAS-815TQ Backplane Specifications B-7 Front Jumper Locations and Pin Definitions C and SGPIO Modes and Jumper Settings JP29 JP18 This backplane can utilize I C or SGPIO. I C is the default mode and can be used without making changes to your jumpers.
  • Page 48 SC815 Chassis Manual B-9 Rear Connectors and LED Indicators H 2 M 4 M 9 M 1 Figure B-5. Rear Connectors and LED Indicators Rear SAS/SATA Connectors Rear Connector SAS Drive Connector Number Number SAS #0 SAS/SATA HDD #0 SAS #1 SAS/SATA HDD #1 SAS #2 SAS/SATA HDD #2...
  • Page 49 Appendix C BPN-SAS3-815TQ Backplane Specifications Appendix C BPN-SAS3-815TQ Backplane Specifications This chapter offers guidelines for personal and equipment safety, and notes about the BPN-SAS3-815TQ version documented in this manual. C-1 ESD Safety Guidelines Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent damage to your system, it is important to handle it very carefully.
  • Page 50 This manual reflects BPN-SAS3-815TQ, Revision 1.00, the most current The following connectors are on the side of the backplane that faces the rear of the release available at the time of publication. Refer to the Supermicro website at chassis. They are marked by silkscreen labels.
  • Page 51 SC815 Chassis Manual Appendix C BPN-SAS3-815TQ Backplane Specifications C-5 Rear Connector Definitions 7. I C Connectors C Connector (JP44) The I C Connectors, designated JP44, are 1. Backplane Main Power Connectors used to monitor HDD activity and status. Pin# Definition Main Power (JP10) Data...
  • Page 52 SC815 Chassis Manual Appendix C BPN-SAS3-815TQ Backplane Specifications C-6 Rear Jumpers and Pin Definitions C and SGPIO Modes and Jumper Settings This backplane can utilize I C or SGPIO. SGPIO is the default mode and can be JP29 JP18 used without making changes to your jumpers. Use the following settings for I JTAG UPGRADE JP29:9071 RST...
  • Page 53 SC815 Chassis Manual Appendix C BPN-SAS3-815TQ Backplane Specifications C-7 Rear LED Indicators C-8 Front Connectors and LED Indicators The front of the backplane has four sockets to connect disk drives, along with LEDs indicators. JTAG UPGRADE JP29:9071 RST JP18:BUZZER RESET JP40 JP42 JP51...
  • Page 54 SC815 Chassis Manual Disclaimer (cont.) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.

Table of Contents