Display When the Power is ON with the Default Settings

p.12
POWER
DRIVER
The BLT-AY-61 and BLT-AY-71 can be switched between 2WS HIGH (20 – 30) and 2WS LOW
(5 – 15) by turning 2WS ON / OFF. The bit can be rotated in reverse by turning REV (reverse
rotation input) ON / OFF.
The torque up number can be set regardless of whether the rotation is forward / reverse
or HIGH / LOW.
Change the number by following the steps in the MODE settings (pages 14 – 15).
In order to prevent the driver from rotating in the case of an accident, the built-in over-
time timer can also be set in the same way regardless of whether the rotation is forward /
reverse or HIGH / LOW.
Change the number by following the steps in the MODE settings (pages 14 – 15).
The factory settings are as follows.
● 2WS
HIGH forward rotation impact number U1
● 2WS
HIGH reverse rotation impact number
● 2WS
HIGH setting speed
● 2WS
HIGH overtime setting value t0 (approximately 42 minutes)
● 2WS
LOW forward rotation impact number d1
● 2WS
LOW reverse rotation impact number
● 2WS
LOW setting speed
● 2WS
LOW overtime setting value t0 (approximately 42 minutes)
● Overload protection function
* For the impact number setting, if you set U0 or d0, torque up does not happen and the impact is contin-
ued (setting without torque up).
 (Note)
 HIGH reverse rotation impact number or LOW reverse rotation impact number should be set at
 U0 or d0 to use the driver for removing screws.
FOR
OPE
TUP
FIN
REV
RES
2WS
OVT
ENT
MODE
30
15
Front panel OL display
When the main SW is turned ON, the green
SW LED light up.
All operation LEDs and the setting value seg-
ment display will turn on for one second.
U0
d0