■ Rear Panel Input / Output

1. Main SW
Inlet with Fuse Holder 3 A / 250 V
Input /
No
Output
1
External Output
2
Common
3
External Input
4
External Input
5
External Input
6
External Input
*1 When the input method is set to pulse, the driver will operate in forward rotation when a FOR input pulse of
100 ms or more is received.
To stop rotation, apply input to the RESET terminal.
The reading input for the start method means that the driver rotates FOR while FOR is input.
To stop the rotation, turn the FOR input OFF or use the RESET input.
Pulse or reading can be switched with the DIP SW on the internal board.
External I/O terminal
Terminal block connector
on the main body
Model number: XW4A-10B1-V1
Signal Name
Output is present on this terminal when screw tight-
ening is complete. Output ceases when either the
FINISH Output
next FOR or REV input is received or when the RESET
input is used.
Common for input and output. This is connected to
COM
the internal controller GND.
Apply input to this terminal when you wish to operate
REV Input
the driver in reverse rotation. The driver will operate
in reverse while the signal is present.
Driver rotation SPEED can switch between two stages.
2WS Input
2WS will be the LOW side while the signal is ON.
Used when the driver operation is to be stopped by
RESET Input
an external source.
Apply input to this terminal when you wish to oper-
FOR Input
ate the driver in forward rotation. The method can be
selected between pulse and reading. *