Tank monitor
Hide thumbs Also See for SeeLevel II:
Table of Contents

Advertisement

4
13" - 17"
17" - 25"
25" - 34"

For single sender applications:

The sender ends should be
bottom of the tank, to allow for the thickness of the tank top and
bottom and any bows in them (see the diagrams). The senders
are calibrated to account for this distance from the bottom of the
tank. The SS sender is cut to the nearest even 2" in length. The ES
sender is cut to the nearest even 1.5" in length, for example, for a
system with a tank height of 11.75", cut the sender to be 10.5" long,
this allows
on the tank. The JS sender is cut to the nearest 1.0" in length.
IMPORTANT: DO NOT cut the 710SS sender shorter than 6". This
sender will not work if it is cut shorter than 6". DO NOT cut the
710ES sender shorter than 4
less than 4
sender will not work if it is cut less than 4".

For double stacked sender applications:

For tall tanks, two stacked 710ES or 710SS senders are used. The
sender ends should be
the tank, to allow for the thickness of the tank top and bottom and
any bows in them (see the diagrams). The senders are calibrated
to account for this distance from the bottom of the tank. In
addition, there needs to be a gap of
two senders. Therefore the total length of both senders will be:
tank height -
sender) or 2" (SS sender) . The top and bottom senders should be
approximately the same length for best results. For example, if the
tank height is 22", then 22"-
of both ES senders will be 21". Make both senders 10.5" long.
7. To make the senders the right length (assuming they are too
long) they will need to cut off with a pair of scissors. The
end to be cut is the bottom end, which is the opposite end
from the top where the wires come out (see the diagrams).
DO NOT cut the sides, and DO NOT cut the 710ES sender
shorter than 4
Page 32
Tank
Height
1/2
" - 5"
5" - 7"
7" - 13"
" at each end when the sender is centered vertically
5/8
1/2
". DO NOT cut the 710JS sender shorter than 4". This
1/4
"-
1/4
"-
1/8
", then rounded down to the nearest 1.5" (ES
1/2
", the 710SS sender shorter than 6" or the

Sender Options

Best Resolution
JS
JS
ES
stacked ES
stacked ES
stacked SS
1/4
" to
3/4
1/2
". This sender will not work if it is cut
1/4
" to
3/4
" away from the top and bottom of
1/4
"-
1/4
"-
1/8
"= 21
Other Acceptable
-
ES
SS
SS
stacked SS
-
" away from the top and
1/16
" to
1/8
" in between the
3/8
", so the total length
709-BTP3 Manual