Summary of Contents for Garnet SeeLevel Access T-DP0301-B
Page 1
MAXIMUM TANK READOUT: ___________________________________________________________________ FULL SCALE ANALOG CALIBRATION VALUE: ___________________________________________________ SERIAL NUMBER : ______________________________________________________________________________ NOTES: _________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ CANADA garnetinstruments.com Garnet US Inc. Garnet Instruments 5360 Old Granbury Road 1-800-617-7384 286 Kaska Road Granbury, TX 76049 Sherwood Park, AB T8A 4G7...
CHAPTER 1 - INTRODUCTION ongratulations on purchasing the Garnet Instruments S L Access ™ Data Portal. The S L Access ™ compliments the S Annihilator ™ 806-B, 806-Bi, or S L Special ™ 808-P2 and SeeLeveL ProSeries II 810-PS2 gauges by providing an additional volume readout in the cab of your truck.
CHAPTER 2 - FEATURES he S L Access ™ has been uniquely designed for specific applications and with specific features: Standard S L Access Features 1. The signal between the 806-B, 806-Bi, 808-P2 or 810-PS2 display and the S L Access ™ is digitally encoded so the signal line can be connected using a standard 7 pin trailer plug.
CHAPTER 3 - WIRING DIAGRAMS HE S L Access ™ has been designed for easy installation with your 806-B, 806-Bi, 808-P2 or 810-PS2 series S L ™ gauge. Installation instructions for the gauge were supplied with the equipment, and are available online at www.garnetinstruments.com The S...
CHAPTER 4 - DISPLAY PROGRAMMING he S L Access ™ display shows the tank level by repeating the information shown on the 806-B, 806-Bi, 808-P2 or 810-PS2 gauge. The 4-20 mA analog output is calculated from the display level with a 4 mA output corresponding to a display level of zero, and a 20 mA output corresponding to the full scale level programmed into the S L Access ™...
Page 8
8. If the full scale calibration is below 103, the display will be unable to calculate a valid calibration, and will show cErr (calibration error) after a few seconds. The existing calibration will be retained, and the display will return to normal operation. To view the existing calibration: 1.
• All messages (SeeLeveL Slave -> ELD MASTER) obey the following format: [Destination: Master address = 0x00] [Originator: Garnet address = 0x19] [total number of bytes in message] [message [payload – optional depending on message] [Checksum (16 bit: 2 bytes)] •...
Page 10
SeeLeveL Query Response (SeeLeveL Slave -> ELD Master) • Value: 0x01 • SeeLeveL responds with model ID (1 byte), H/W Rev (1 byte), S/W Rev (2 bytes), alarm capability (1 byte), and SN support (1 byte). If the SeeLeveL device supports a unique serial number, it will follow (8 bytes in length).
Page 11
Send Liquid Level Message (ELD Master -> SeeLeveL Slave) • Value: 0x05, no payload • SeeLeveL responds with a single liquid level or a handshake demand message. • [0x19][0x00][0x06][0x05][ 0x00][0x24] SeeLeveL Query Alarm Liquid Level Message (ELD Master -> SeeLeveL Slave) •...
Page 12
SeeLeveL Error Response (SeeLeveL Slave -> ELD Master) • Value: 0x0F, 1 byte payload • SeeLeveL issues this response if a command/message is not supported. Payload = unsupported message code. • Example: ELD has previously issued a SeeLeveL Query Alarm Liquid Level Message (0x07) to a SeeLeveL device which does not support alarms: •...
Page 13
• ELD sends handshake response • SeeLeveL sends reply to original ELD request if handshake response is correct and on time. • The “handshake accepted acknowledge” message is not used here. • Upon power-up of the display, the “20 requests” is reset so a handshake is needed for the first liquid level request.
CHAPTER 6 - TROUBLESHOOTING GUIDE Error Code Cause Solution The display is not receiving any signal from the 806-B, 806-Bi, 808-P2 or 810-PS2 Check the wiring gauge. and grounding for errors or bad no S The analog output will go connections.
CHAPTER 7 - SPECIFICATIONS "0.25% of full scale value Analog output accuracy: ± 0.05 mA" Minimum input supply voltage: +10.0 V Minimum difference between input supply voltage and voltage on analog 4.0 V 4-20 mA output: Current drain: 200 mA or less Temperature range: -40°C to +60°C (-40°F to +140°F) Material: Aluminum...
Alberta, T8A 4G7. Returned warranted items will be repaired or replaced at the discretion of Garnet Instruments. Any Garnet items under the Garnet Warranty Policy that are deemed irreparable by Garnet Instruments will be replaced at no charge or a credit will be issued for that item subject to the customer’s request.