Garnet SeeLeveL II 709 Series Installation Manual & User Manual

Garnet SeeLeveL II 709 Series Installation Manual & User Manual

Holding tank monitor

Advertisement

Quick Links

HOLDING TANK MONITORS
DISPLAY INSTALLATION GUIDE
& USER MANUAL FOR 709 SERIES
709-2P
|
709
|
709-P3
709-BTP3
|
709-RVC
|
709-N2K NLP
|
709-4
CANADA
USA
Garnet Instruments
Garnet US Inc.
286 Kaska Road
5360 Old Granbury Road
Sherwood Park, AB T8A 4G7
Granbury, TX 76049
SeeLeveL II 709 Series Display Manual
|
709-P3W
|
709-HP3W
709-RVC PM
|
709-RVC NLP
|
709-4P
|
709-4LP

INTRODUCTION

Through decades of experience and development the SeeLeveL tank
monitor series has established itself as the gold standard in level
measurement technology for the Recreational Vehicle industry.
The SeeLeveL II™ has a combination of features, accuracy, reliability, and
diagnostic capability that provide the best possible user experience.
Depending on the model, the SeeLeveL II monitors battery voltage, and
displays percentage of full readouts for FRESH, GREY, GALLEY, and BLACK
tank levels. In addition, the system can display the operating characteristics
of each of the tank sending units, giving it unsurpassed diagnostic
capability.
Document the following information for future reference. See page 4 for
more information.
Model Number: ___________________________________________________________
Serial Number: ____________________________________________________________
Date of purchase: _________________________________________________________
709 Series Manual_v1.0 - 21-Oct-2022
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Garnet SeeLeveL II 709 Series

  • Page 1: Introduction

    Serial Number: ____________________________________________________________ Date of purchase: _________________________________________________________ 709 Series Manual_v1.0 - 21-Oct-2022 CANADA Garnet Instruments Garnet US Inc. 286 Kaska Road 5360 Old Granbury Road Sherwood Park, AB T8A 4G7 Granbury, TX 76049 SeeLeveL II 709 Series Display Manual Page 1...
  • Page 2: Table Of Contents

    Transmitted, transcribed, stored in a retrieval system or translated into any language in any form by any means without the prior written consent of Garnet Instruments. Information in this manual is subject to change without notice and does not represent a commitment on the part of GARNET.
  • Page 3: About The System

    NMEA 2000 Network (If equipped) the diagnostic information. Model 709-N2K NLP is NMEA 2000 Network compatible, the tank levels and capacity are available on the NMEA Bus. SeeLeveL II 709 Series Display Manual Page 3...
  • Page 4: Series Model Features Table

    Optional items available to purchase if required. Go to our website for more information: □ Filler Panel to fit previous display hole that is too large. □ Gasket to prevent the display monitor from shorting if mounting to a metal surface. SeeLeveL II 709 Series Display Manual Page 4...
  • Page 5: Display Installation

    A relay may be required for models with a pump or heater switch. help prevent damaging the display. Contact Garnet or go to our website for further details. More installation tips are available in the “Troubleshooting and Installation Tips” section.
  • Page 6: Operation Guide

    5 minutes. To end the hold mode sooner, time-out is restarted every time a button is FRESH 1 2 . 0 press any tank button and display will shut BATT pressed. off. LEVEL IN PERCENT LEVEL IN PERCENT SeeLeveL II 709 Series Display Manual Page 6...
  • Page 7: Rv-C Bus Communication (If Equipped)

    0 for fresh, 1 for black, 2 for grey and 18 for galley (depending how the The 709-N2K reports as NMEA device class 75 (sensor communication interface) with an NMEA function code of 150 (fluid level). Garnet display is equipped). The LPG sensor uses a default source address of 73 and a SPN-ISB instance of 3.
  • Page 8: Configuration Guide

    Each tank will need to be calibrated individually using this procedure. CAUTION: For displays that have a GALLEY button the GREY and GALLEY tanks can only have one sender per tank and cannot be stacked. SeeLeveL II 709 Series Display Manual Page 8...
  • Page 9: Calibrate The Lpg Sender (If Equipped)

    FRESH tank button to  FRESH decrease. 4. When the display shows the correct tank capacity, press the BATT button to save BATT changes and exit programming mode. SeeLeveL II 709 Series Display Manual Page 9...
  • Page 10: Configuration Guide (Bluetooth Model Only)

    The BATT button saves and returns to the previous menu. BATT (Hi level alarm at 90%, included in H 9 0 . the common alarm and fail to full.) LEVEL IN PERCENT SeeLeveL II 709 Series Display Manual Page 10...
  • Page 11: Program The Display As Primary Or Secondary

    LEVEL IN PERCENT LEVEL IN PERCENT LEVEL IN PERCENT are the software version. When viewing is release both buttons to return to normal complete, release both buttons to return to operation. normal operation. SeeLeveL II 709 Series Display Manual Page 11...
  • Page 12: Troubleshooting Guide

    If the wiring to O P n the LPG sender is shorted then the LPG will always show “0”. LEVEL IN PERCENT NOTE: There are no diagnostics for battery voltage. SeeLeveL II 709 Series Display Manual Page 12...
  • Page 13: Rv-C Diagnostics (If Equipped)

    LEVEL IN PERCENT left digit, for example “h 6” indicates that the sender has 6 receive segments. 6. After 5 seconds of showing the height, the display will shut off. LEVEL IN PERCENT SeeLeveL II 709 Series Display Manual Page 13...
  • Page 14: Wiring Diagnostics

    Wiring Diagnostics OPEN CIRCUIT O P n Shows? SINGLE S h t S h t Shows? Shows? S h t Shows? SeeLeveL II 709 Series Display Manual Page 14...
  • Page 15 SHORT CIRCUIT S h t Shows? S h t Remains? S h t Disappears when a sender is disconnected? S h t S h t Comes back on when sender reconnected? SeeLeveL II 709 Series Display Manual Page 15...
  • Page 16: Troubleshooting & Installation Tips

    Tissue Digester, Sensor Cleaner, or the latest proper level calculation and sender operation. we have used called Happy Campers Holding Tank Extreme Cleaner available at www.happycampersworld.com. The next time you take a trip, leave with SeeLeveL II 709 Series Display Manual Page 16...
  • Page 17 90 degree angle to the sender orientation, with the wiring held in place by the tape. The wires from the sender must be routed straight up or to the right for reliable operation. SeeLeveL II 709 Series Display Manual Page 17...
  • Page 18: Warranty & Service Information

    Alberta, T8A 4G7. Returned warranted items will be repaired or replaced at the discretion of Garnet Instruments. Any Garnet items under the Garnet Warranty Policy that are deemed irreparable by _______________________________________________________________________________ Garnet Instruments will be replaced at no charge or a credit will be issued for that item subject to the customer’s request. _______________________________________________________________________________...

Table of Contents