As these requirements can be met only
after sufficient and constant practice:
8VH D ILOH KROGHU*
A file holder must be used for manual
resharpening of Super chain. The correct
filing angle is marked on the file holder.
90°
85° 70°
80°
60°
30°
35°
10°
)RU FKHFNLQJ DQJOHV
STlHL filing gauge* (see table)
A universal tool for checking the filing
and side plate angles, depth gauge
setting and cutter length. Also cleans the
guide bar groove and oil inlet hole.

)LOH FRUUHFWO\
If you use a file holder or the FG 1:
Leave the chain on the bar.
Clamp the bar in a vise if necessary.
Lock the chain - push hand guard
forward
To rotate the chain - pull hand
guard against front handle
Sharpen chain frequently, take
away as little metal as possible -
two or three strokes of the file are
usually enough
Always file from the inside to the
outside of the cutter.
The file only sharpens on the
forward stroke -
lift the file off the cutter on the back-
stroke.
Hold the file KRUL]RQWDOO\ for all
chain types (at right angle to side of
guide bar) and file according to the
angles marked on the filing tool.
Avoid touching the tie straps and
drive links with the file.
Rotate the file at regular intervals
while filing -
this avoids one-sided wear.
90°
Use a piece of hardwood to remove
burrs from cutting edge.
Check angles with the filing gauge.
$OO FXWWHUV PXVW EH WKH VDPH OHQJWK
If the cutters are not the same length,
they will have different heights. This
makes the chain run roughly and can
cause it to break.
Find the shortest cutter and then file all
other cutters back to the same length.
This can be very time consuming - it is
best to have it done in the workshop on
an electric grinder.
* Special accessory