We recommend STIHL 50:1 two-stroke
engine oil since it is specially formulated
for use in STIHL engines.
Do not use BIA or TCW (two-stroke
water cooled) mix oils!
Take care when handling gasoline.
Avoid direct contact with the skin and
avoid inhaling fuel vapour
(see "Safety Precautions").
The canister should be kept tightly
closed in order to avoid any moisture
getting into the mixture.
The fuel tank and the canister in which
fuel mix is stored should be cleaned
from time to time.
)XHO PL[ DJHV
Only mix sufficient fuel for a few days
work, not to exceed 3 months of storage.
Store in approved safety fuel-canisters
only. When mixing, pour oil into the
canister first, and then add gasoline.
Gaso-
Oil (STIHL 50:1 or
line
equivalent branded TC oils)
US gal.
US fl.oz
1
2.6
2 1/2
6.4
5
12.8
Dispose empty mixing-oil canisters only
at authorized disposal locations.
 46
)XHOLQJ
Before fueling, clean the fuel filler cap
and the area around it to ensure that no
dirt falls into the tank.
Always thoroughly shake the mixture in
the canister before fueling your machine.
:DUQLQJ
In order to reduce the risk of burns or
other personal injury from escaping gas
vapor and fumes, remove the fuel filler
cap carefully so as to allow any pressure
build-up in the tank to release slowly.
:DUQLQJ
After fueling, tighten fuel cap DV
VHFXUHO\ DV SRVVLEOH by hand.
Use a suitable tool (e.g. screwdriver end
of combination wrench) to tighten
slotted fuel caps.
Change the fuel pick up body every year.
Before storing your machine for a long
period, drain and clean the fuel tank and
run engine until carburetor is dry.


Hide quick links: